CAUTION:
The 8/80 and Encryption SAN Switches use two power cords. Disconnect both power cords before
servicing.
To replace a fan assembly:
1.
Use a Phillips-head screwdriver to unscrew the captive screw on the fan assembly you are
replacing.
2.
Remove the fan assembly from the chassis by pulling the handle out, away from the chassis.
3.
Install the new fan assembly in the chassis:
a.
Orient the new fan assembly as shown in
Figure 33
, with the captive screw on the right.
b.
Gently push the fan assembly into the chassis until it is firmly in.
CAUTION:
Do not force the installation. If the fan assembly does not slide in easily, ensure that it
is correctly oriented before continuing.
c.
Secure the fan assembly to the chassis with the captive screw.
4.
Verify that the fan status LED is lit steady green to indicate normal operation (see
Table 16
).
5.
Optionally, display the fan status using the
fanShow
command from the CLI (see
Figure 33
for
the locations of Fan assembly #1, Fan assembly #2, and Fan assembly #3).
8-Gb SAN Switch hardware reference manual
75
Summary of Contents for StorageWorks 8/24 - SAN Switch
Page 10: ...10 ...
Page 54: ...Installing and configuring an 8 Gb SAN Switch 54 ...
Page 80: ...Managing the 8 Gb SAN Switches 80 ...
Page 92: ...Technical Specifications 92 ...
Page 104: ...Regulatory compliance and safety 104 ...
Page 106: ...Electrostatic discharge 106 ...
Page 110: ...110 ...