Removal and replacement procedures 41
CAUTION:
To avoid data loss, be sure that the drives are labeled and returned to the same
bays they were removed from.
6.
Be sure that the hard drive drawer is closed.
7.
Remove all I/O modules ("
Hot-plug I/O module
" on page
32
).
8.
Remove the power block ("
Power block
" on page
39
).
9.
Remove the hard drive drawer ("
Hard drive drawer
" on page
34
).
10.
Remove the four T-10 Torx screws securing the fan cage to the hard drive drawer, and then remove
the fan cage.
11.
Remove the two T-15 Torx screws securing the fan board to the hard drive drawer, and then remove
the fan board, being careful not to disconnect the two cables.