Troubleshooting Guide
www.hp.com
A–9
POST Error Messages
1201-System Audio
Address Conflict
Detected
Device IRQ address
conflicts with another
device.
Reset the IRQ.
1202-MIDI Port
Address Conflict
Detected
Device IRQ address
conflicts with another
device.
Reset the IRQ.
1203-Game Port
Address Conflict
Detected
Device IRQ address
conflicts with another
device.
Reset the IRQ.
1611-Fan failure
detected
Chassis fan not
connected to the system
board.
1. Reconnect the fan.
2. Replace the fan.
3. Replace the system board.
1720-SMART Hard
Drive Detects
Imminent Failure
Hard drive is about
to fail. (Some hard
drives have a firmware
patch that will fix an
erroneous error
message.)
1. Determine if hard drive is giving
correct error message.
2. Apply firmware patch if applicable.
(Visit
www.hp.com/support
)
3. Back up contents and replace hard
drive.
1721-SMART SCSI
Hard Drive Detects
Imminent Failure
Hard drive is about
to fail. (Some hard
drives have a firmware
patch that will fix an
erroneous error
message.)
1. Determine if hard drive is giving
correct error message.
2. Apply firmware patch if applicable.
3. Back up contents and replace hard
drive.
Numeric Codes and Text Messages