Contents 35
Table 20
POST Error Messages
Error code
Error message Description/corrective action
625 Uncorrectable
Memory
ECC Error -
DIMM_J106
There is one Uncorrectable Memory ECC Error occurred on the
DIM_J106 during the system running last time. Replace this DIMM with
another one.
626 Uncorrectable
Memory
ECC Error - DIMM_J7J8
Set the Memory Channel Mode as “Independent” and the Uncorrectable
Memory ECC error occurred on the DIMM_J7 or DIMM_J8, then
replace the broken DIMM
627 Uncorrectable
Memory
ECC Error -
DIMM_J9J10
Set the Memory Channel Mode as “Independent” and the Uncorrectable
Memory ECC error occurred on the DIMM_J9 or DIMM_J10, then
replace the broken DIMM
628 Uncorrectable
Memory
ECC Error -
DIMM_J11J12
Set the Memory Channel Mode as “Independent” and the Uncorrectable
Memory ECC error occurred on the DIMM_J11 or DIMM_J12, then
replace the broken DIMM
629 Uncorrectable
Memory
ECC Error -
DIMM_J13J14
Set the Memory Channel Mode as “Independent” and the Uncorrectable
Memory ECC error occurred on the DIMM_J13 or DIMM_J14, then
replace the broken DIMM
62A Uncorrectable
Memory
ECC Error -
DIMM_J100J101
Set the Memory Channel Mode as “Independent” and the Uncorrectable
Memory ECC error occurred on the DIMM_J100 or DIMM_J101, then
replace the broken DIMM
62B Uncorrectable
Memory
ECC Error -
DIMM_J102J103
Set the Memory Channel Mode as “Independent” and the Uncorrectable
Memory ECC error occurred on the DIMM_J102 or DIMM_J103, then
replace the broken DIMM
62C Uncorrectable
Memory
ECC Error -
DIMM_J104J105
Set the Memory Channel Mode as “Independent” and the Uncorrectable
Memory ECC error occurred on the DIMM_J104 or DIMM_J105, then
replace the broken DIMM
62D Uncorrectable
Memory
ECC Error -
DIMM_J106J107
Set the Memory Channel Mode as “Independent” and the Uncorrectable
Memory ECC error occurred on the DIMM_J106 or DIMM_J107, then
replace the broken DIMM
Checking
NVRAM
Update Failed
BIOS could not write to the NVRAM block. This message appears when
the FLASH part is malfunctioning.
Operating system not
found
Operating system cannot be located on any of the boot drives.
Verify that the priority boot drive has power and that the IDE
cable is connected properly.
Verify that the desired boot drive has power
Verify that the IDE cable is securely plugged into the respective
system board connectors.
Verify that the boot device is enabled in the Setup Utility.
Verify that the boot device has an operating system installed.
If the problem persists, contact your Foxconn Customer Support
provider.
Summary of Contents for ProLiant SL165z - G6 Server
Page 44: ...Contents 44 ...