Contents 17
Table 10
Serial Port Configuration submenu fields
Field
Description Options
Serial Port Assignment
This setting will assign the serial port connector to the system. This is
the default setting.
System
This setting will assign the serial port connector to the BMC
(Baseboard management controller).
BMC
Serial Port Switching
This setting allows the Serial port switch between system and BMC.
This is the default setting
Enabled
This setting will prevent the Serial port from switching between
system and BMC.
Disabled
Serial Port Connection
Mode
Serial port connection mode is Direct. This is the default setting
Direct
Serial port connection mode is Modem
Modem
Figure 13
LAN Configuration submenu
Table 11
LAN Configuration submenu fields
Field
Description
Options
Share NIC Mode
Setting this value will prevent support from share NIC mode
Disabled
Setting this value will allow support share NIC mode.(Disabled the
KVM).
Enabled
DHCP IP Source
Setting this value will allow dynamic IP assignment.
Enabled
Setting this value will allow manual IP assignment.
Disabled
Summary of Contents for ProLiant SL165z - G6 Server