background image

 

 

Illustrated parts catalog  25  

 

 

HP Contact Information  

For the name of the nearest HP authorized reseller:  

 

In the United States, call 1-800-345-1518. 

 

In Canada, call 1-800-263-5868. 

 

In other locations, refer to the HP website at 

http://www.hp.com/

For HP technical support:  

 

In North America: 

 

Call 1-800-HP-INVENT (1-800-474-6836). This service is available 24 hours a day, 7 days 

a week. For continuous quality improvement, calls may be recorded or monitored. 

 

If you have purchased a Care Pack (service upgrade), call 1-800-633-3600. For more 

information about Care Packs, refer to the HP website at 

http://www.hp.com/

 

Outside North America, call the nearest HP Technical Support Phone Center. For telephone 

numbers for worldwide Technical Support Centers, refer to the HP website at 

http://www.hp.com/

Before You Contact HP  

Be sure to have the following information available before you call HP: 

 

Technical support registration number (if applicable) 

 

Product serial number 

 

Product model name and number 

 

Applicable error messages 

 

Add-on boards or hardware 

 

Third-party hardware or software 

 

Operating system type and revision level 

Summary of Contents for ProLiant SL165s G7

Page 1: ...HP ProLiant SL165s G7 Server Maintenance and Service Guide Part number 635252 001 First edition March 2011 ...

Page 2: ...services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Intel is a trademark of Intel Corporation in the U S and other countries AMD is a trademark of Advanced Micro Devices Inc ...

Page 3: ... 29 Drives and Cable Management 30 Cable Management 30 Cable Connections 32 Hard Drives 33 Front I O Panel 36 System Board Configuration 37 Processor 37 Memory 42 PCI Expansion Cards 45 CPU DIMM Air Baffle 47 Battery backed write cache BBWC 48 System Battery 49 System Board Removal and Replacement Procedure 51 Power Supply Unit PSU 52 System Fan 53 Connectors Switches and LEDs 56 Connectors and Co...

Page 4: ...y Menu Bar 67 BIOS Update 73 Clear CMOS 74 Power on Self Test POST 74 POST Error Indicators 75 POST Errors Message Definition 75 POST Related Troubleshooting 76 Physical and Operating Specifications 77 System Unit 77 Index 80 ...

Page 5: ... be shipped for next business day delivery Same day or four hour delivery may be offered at an additional charge where geography permits If assistance is required you can call the HP Technical Support Center and a technician will help you over the telephone HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP In cases where it is require...

Page 6: ...èces CSR sont livrées le jour ouvré suivant dans la limite des stocks disponibles et selon votre situation géographique Si votre situation géographique le permet et que vous demandez une livraison le jour même ou dans les 4 heures celle ci vous sera facturée Pour bénéficier d une assistance téléphonique appelez le Centre d assistance technique HP Dans les documents envoyés avec la pièce de rechang...

Page 7: ... con consegna entro il giorno lavorativo seguente La consegna nel giorno stesso o entro quattro ore è offerta con un supplemento di costo solo in alcune zone In caso di necessità si può richiedere l assistenza telefonica di un addetto del centro di supporto tecnico HP Nel materiale fornito con una parte di ricambio CSR HP specifica se il cliente deve restituire dei componenti Qualora sia richiesta...

Page 8: ...innerhalb von vier Stunden gegen einen Aufpreis verfügbar Wenn Sie Hilfe benötigen können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen Den Materialien die mit einem CSR Ersatzteil geliefert werden können Sie entnehmen ob das defekte Teil an HP zurückgeschickt werden muss Wenn es erforderlich ist das defekte Teil an HP zurückzuschicken müssen...

Page 9: ...stino al siguiente día laborable Si la situación geográfica lo permite se puede solicitar la entrega en el mismo día o en cuatro horas con un coste adicional Si precisa asistencia técnica puede llamar al Centro de asistencia técnica de HP y recibirá ayuda telefónica por parte de un técnico Con el envío de materiales para la sustitución de componentes CSR HP especificará si los componentes defectuo...

Page 10: ...onden voor levering op de eerstvolgende werkdag Levering op dezelfde dag of binnen vier uur kan tegen meerkosten worden aangeboden indien dit mogelijk is gezien de locatie Indien assistentie gewenst is belt u een HP Service Partner om via de telefoon technische ondersteuning te ontvangen HP vermeldt in de documentatie bij het vervangende CSR onderdeel of het defecte onderdeel aan HP moet worden ge...

Page 11: ...rimeiro dia útil após o pedido Onde as condições geográficas permitirem a entrega no mesmo dia ou em quatro horas pode ser feita mediante uma taxa adicional Se precisar de auxílio entre em contato com o Centro de suporte técnico da HP para que um técnico o ajude por telefone A HP especifica nos materiais fornecidos com a peça CSR de reposição se a peça com defeito deve ser devolvida à HP Nos casos...

Page 12: ...Customer self repair 12 ...

Page 13: ...Customer self repair 13 ...

Page 14: ...Customer self repair 14 ...

Page 15: ...Customer self repair 15 ...

Page 16: ...ription Spare part number Customer self repair 1 SL165s chassis N A N A 2 Front panel N A N A 3 CPU air baffle N A N A 4 DIMM air baffle N A N A 5 Power Cable bracket N A N A 6 X4 riser bracket N A N A 7 SL165s system tray N A N A 8 X16 riser bracket N A N A 9 Power Supply cover N A N A ...

Page 17: ...remplacement de la pièce soit effectué par un Mainteneur Agréé Ces pièces sont identifiées par la mention Non dans le Catalogue illustré 1 Mandatory Obbligatorie Parti che devono essere necessariamente riparate dal cliente Se il cliente ne affida la riparazione ad HP deve sostenere le spese di spedizione e di manodopera per il servizio 2 Optional Opzionali Parti la cui riparazione da parte del cli...

Page 18: ...w rekening 2 Optional Optioneel Onderdelen waarvoor reparatie door de klant optioneel is Ook deze onderdelen zijn ontworpen voor reparatie door de klant Als u echter HP verzoekt deze onderdelen voor u te vervangen kunnen daarvoor extra kosten in rekening worden gebracht afhankelijk van het type garantieservice voor het product 3 No Nee Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door...

Page 19: ...Illustrated parts catalog 19 ...

Page 20: ... PCIe card N A N A 4 PCIe X16 riser card 632825 001 Optional2 5 Front BD EATX N A N A 6 HeatSink for processor 1 637976 001 Mandatory1 HeatSink for processor 2 603888 001 Mandatory1 7 Memory Module DIMM 2GB PC3 10600R 128M x 8 595094 001 Mandatory1 DIMM 4GB PC3 10600R 512M x 4 595096 001 Mandatory1 RDIMM 4GB PC3L 10600R 512M x 4 606424 001 Mandatory1 RDIMM 8GB PC3L 10600R 512M x 4 606425 001 Manda...

Page 21: ...65 system N A N A 11 Non Redundant Fan 600659 001 Mandatory1 Redundant Fan 620197 001 Mandatory1 12 AC power board N A N A 13 PCA M B DL165G7 enhanced 651908 001 Optional2 14 1200 W Power Supply 1200 W Power Supply High Efficiency 498152 001 579229 001 Mandatory1 750 W Power Supply 750 W Power Supply High Efficiency 599383 001 511778 001 Mandatory1 15 Power convert cable 24P 632816 001 Optional2 1...

Page 22: ...e le remplacement de la pièce soit effectué par un Mainteneur Agréé Ces pièces sont identifiées par la mention Non dans le Catalogue illustré 1 Mandatory Obbligatorie Parti che devono essere necessariamente riparate dal cliente Se il cliente ne affida la riparazione ad HP deve sostenere le spese di spedizione e di manodopera per il servizio 2 Optional Opzionali Parti la cui riparazione da parte de...

Page 23: ...w rekening 2 Optional Optioneel Onderdelen waarvoor reparatie door de klant optioneel is Ook deze onderdelen zijn ontworpen voor reparatie door de klant Als u echter HP verzoekt deze onderdelen voor u te vervangen kunnen daarvoor extra kosten in rekening worden gebracht afhankelijk van het type garantieservice voor het product 3 No Nee Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door...

Page 24: ...Illustrated parts catalog 24 ...

Page 25: ...u have purchased a Care Pack service upgrade call 1 800 633 3600 For more information about Care Packs refer to the HP website at http www hp com Outside North America call the nearest HP Technical Support Phone Center For telephone numbers for worldwide Technical Support Centers refer to the HP website at http www hp com Before You Contact HP Be sure to have the following information available be...

Page 26: ... Configuration Tools You need the following items for some procedures T 10 T 15 wrench The following references and software tools may also be used HP ProLiant SL165s G7 Server Support CD IPMI Event Log Diagnostics Software Hardware Configuration Information Electrostatic Discharge Information An electrostatic discharge ESD can damage static sensitive devices or microcircuit Proper packaging and g...

Page 27: ...nt 1 Be sure all components are installed according to the described step by step instructions 2 Reinstall the rear cage air baffle peripherals and system cables that you have removed 3 Reinstall server into rack 4 Connect all external cables and the AC power cord to the system 5 Press the power button on the front panel to turn on the server Server Warnings and Cautions Before installing a server...

Page 28: ...nnections to the branch circuit e g use of power strips Symbols on Equipment The following symbols may be placed on equipment to indicate the presence of potentially hazardous conditions This symbol indicates the presence of hazardous energy circuits or electric shock hazards Refer all servicing to qualified personnel To reduce the risk of injury from electric shock hazards do not open this enclos...

Page 29: ...hut down server as directed by the operating system documentation 2 Press the power button to toggle to Standby This places the server in standby mode changing the power LED indicator to amber In this mode the main power supply output is disabled Standby does not completely disable or remove power from the system 3 Disconnect the AC power cord from the AC outlet and then from the server 4 Be sure ...

Page 30: ...rd into the chassis Drives and Cable Management Cable Management Always follow good cable management practices when working inside the computer Keep cables away from major heat sources like the heat sink Do not jam cables on top of expansion cards or memory modules Printed circuit cards are not designed to withstand excessive pressure Keep cables clear of sliding or moveable parts to prevent cutti...

Page 31: ... in radius Never crease a SATA data cable Do not rely on components like the drive cage power supply or system cover to push cables down into the chassis To remove power supply cables from the system board connectors J36 1 Squeeze on the top of the retaining latch attached to the cable end of the connector 2 Grasp the cable end of the connector and pull it straight up CAUTION Always pull the conne...

Page 32: ... J16 J17 J18 J19 J21 J22 J23 J24 The following table provides the system board designators that various cables plug into For more detailed information about system board components see system board components Table 2 Node Cable connections Cable To System Board Designator Power convert cable Node 24 pin Power Connector J52 Power convert cable Node 8 pin Power Connector J53 Power convert cable Node...

Page 33: ...n Item Description 1 LFF SAS SATA Hard Drive 1 2 LFF SAS SATA Hard Drive 2 3 LFF SAS SATA Hard Drive 3 4 LFF SAS SATA Hard Drive 4 5 LFF SATA Hard Drive 5 6 LFF SATA Hard Drive 6 To install a LFF Hard Drive 1 Unlock the HDD carrier latch 2 Rotate the HDD carrier handle up 3 Insert the HDD carrier and align the four pins 4 Rotate the HDD carrier handle down and then lock the HDD carrier latches ...

Page 34: ...acement Procedures 34 Figure 5 Installing the LFF hard drive assembly To remove the LFF hard drive 1 Slide the HDD carrier latches to unlock the HDD handle 2 Raise the HDD handle 3 Lift the HDD assembly out of the tray ...

Page 35: ...ation Item Description HDD1 Under HDD5 SFF SAS SATA Hard Drive 1 HDD2 Under HDD6 SFF SAS SATA Hard Drive 2 HDD3 Under HDD7 SFF AS SATA Hard Drive 3 HDD4 Under HDD8 SFF SAS SATA Hard Drive 4 HDD5 SFF SAS SATA Hard Drive 5 HDD6 SFF SAS SATA Hard Drive 6 HDD7 SFF SAS SATA Hard Drive 7 HDD8 SFF SAS SATA Hard Drive 8 ...

Page 36: ... the server Voltages are present at various locations within the server whenever an AC power source is connected This voltage is present even when the main power switch is in the off position Front I O Panel To remove the front I O panel 1 Unfasten the screws that secure the front I O panel to the tray 2 Remove the front I O panel Figure 8 Removing the front I O panel To install the Front I O pane...

Page 37: ...talled in processor socket 1 However if processor 1 fails the system automatically boots from processor 2 and provides a processor failure message The processor socket supports AMD Opteron 6132HE processor AMD Opteron 6166HE processor AMD Opteron 6140 processor AMD Opteron 6176 processor AMD Opteron 6128 processor AMD Opteron 6136 processor AMD Opteron 6172 processor CAUTION It is recommended to u...

Page 38: ...n and removal procedures use a diagonally opposite pattern an X pattern when loosening and tightening the two spring loaded screws Do not over tighten the heat sink s spring loaded screws to prevent them from breaking off A maximum torque of 4 in Ib is set for the system 1 Loosen the two mounting pins 2 Lift the heat sink away from the system board 3 Lift the heat sink frame away from the system b...

Page 39: ...n a previously installed processor it is critical that you apply more thermal interface material to the integrated heat spreader on the processor to ensure proper thermal bonding between the processor and the heat sink To remove a processor 1 Disengage the load lever 2 Lift the retention plate to expose the socket body 3 Use the processor installation tool to grasp the processor 4 Lift the process...

Page 40: ...r into the socket The processor and system board spare part kits contain the processor install tool and instructions on how to use the tool It is important to follow the instructions to prevent damage to the pins in the processor socket To install the new processor 1 Insert the processor in the tool 2 Align the processor installation tool with the socket and install the processor Figure 14 Install...

Page 41: ...ct surfaces significantly reducing the ability of the heat sink to draw out heat Installing the heat sink with excessive grease can also cause the grease to spread over the processor pins or the system board base which can cause electrical shorts that damage the system To install the heat sink CAUTION To prevent overheating or a possible system crash use only a heat sink model specified for the HP...

Page 42: ...L165s G7 server with four trays has 96 DIMM slots that support up to 1024GB maximum system memory You must adhere to the following guidelines when adding or replacing memory modules For 8P system both physical processors in each node must be of the same type and speed Use 800 1066 1333 MHz Registered Unbuffered ECC DDR3 Memory Supported DIMM 2 GB 4GB 8GB and 16GB 1024GB maximum capacity DDR3 ...

Page 43: ...NOTE SR Single Rank DR Dual Rank QR Quad Rank Population rules must be followed for both processors Memory modules may be populated one at a time per processor but populating two at a time per processor provides better performance Memory modules should be populated four at a time per processor for best performance Quad Rank memory module can only be installed in memory sockets 2 5 8 and 11 To remo...

Page 44: ... the DIMM slot and then press the module fully into the slot 2 Firmly press the holding clips inward to secure the memory module in place Figure 20 Installing a Memory module CAUTION The memory slots are structured to ensure proper installation If you insert a memory module but it does not fit easily into the slot you may have inserted it incorrectly Double check the orientation of the module and ...

Page 45: ...s on the system boards Figure 21 PCIe x16 slot location on 165 system board Item Component Designator Component Function 1 PCIe slot PCIe x16 slot Supports PCIe x16 Riser Card Figure 22 PCIe x4 Riser Card slot Location on 165 system board Item Component Designator Component Function 1 PCIe slot PCIe x4 slot Supports PCIe x4 Riser Card ...

Page 46: ...of the arrow shown in step 2 to separate the CPU air baffle and then remove the bracket away together with the riser cards Figure 23 Removing the PCIe riser card assembly Install PCIe bracket assembly To install the PCIe bracket with PCIe riser cards 1 Align the riser card connector with the slot on the system board and then inset the assembly into the slot 2 Fasten the screws to secure the bracke...

Page 47: ...NOTE The DIMM air baffle is required for proper thermal solution To install the DIMM air baffle 1 Hold the latch on the top of the DIMM air baffle and align it to the system board 2 Press down to make sure the DIMM air baffle completely installed NOTE To check and ensure the 2 ribs are installed between DIMM1 and DIMM2 DIMM11 and DIMM12 ...

Page 48: ... the CPU air baffle 1 Align the CPU air baffle to the tray 2 Secure the left latch to the left bracket the middle latch to the middle bracket and the right latch to the PCIe x16 bracket on the tray 3 Press down the CPU air baffle to make sure it completely installed on the tray Figure 26 Installing the CPU air baffle into the tray Battery backed write cache BBWC To install the BBWC bracket ...

Page 49: ...lightly press the top of the BBWC bracket as shown in step 1 2 Install the BBWC into the tray and slide it in the direction of the arrow Figure 28 Installing the BBWC System Battery The server uses nonvolatile memory that requires 1 battery to retain system information when power is removed This 3 volt lithium coin cell battery is located on the system board ...

Page 50: ...d batteries according to manufacturer s instructions CAUTION Loss of BIOS settings occurs when the battery is removed You must reconfigure BIOS settings whenever you replace the battery NOTE If the server no longer automatically displays the correct date and time you may need to replace the system battery Under normal usage battery life is five to ten years To replace the system battery 1 To relea...

Page 51: ...e screws that secure the system board to the tray 2 Release the system board from the tray Figure 31 Removing the 165 system board from the tray To install the 165 system board 1 Put the system board in the chassis The nine screw holes on the chassis should align with the system board 2 Fasten the nine screws on the system board to secure the system board to the chassis ...

Page 52: ...ote of the following reminders to reduce the risk of personal injury from electric shock hazards and or damage to the equipment Installation of power supply units should be referred to individuals who are qualified to service server systems and are trained to deal with equipment capable of generating hazardous energy levels DO NOT open the power supply unit There are no serviceable parts inside it...

Page 53: ... out of the power cage 2 Align the power supply cage connector with the open slot of power supply 3 Slide the power supply into the power supply bay until it snaps into place Figure 35 Installing the power supply System Fan The server can support 8 system fans located at the chassis rears fan cage The figure below identifies the system fans by their device number and shows their corresponding cabl...

Page 54: ... board NOTE A new system fan can be installed to allow the server to operate properly in case a default system fan becomes defective To remove the system fan 4 Squeeze the two release tabs on the system fan together to release it from the chassis 5 Lift the system fan away from the chassis Figure 37 Removing the system fan To replace the system fan 1 Insert the system fan into the fan bracket ...

Page 55: ...Removal and Replacement Procedures 55 Figure 38 Installing the system fan ...

Page 56: ...front panel rear panel system board and hard drives of the HP ProLiant SL165s Generation 7 Connectors and Components Front Panel Components Figure 39 Front panel components of SL165s G7 server system Item Description 1 UID LED switch 2 Serial Port 3 Top NIC Connector Bottom NIC Connector 4 Server tray 1 5 Server tray 2 6 Server tray 3 7 Power LED switch 8 Health LED 9 NIC1 connector 10 NIC2 connec...

Page 57: ...t Bottom USB 2 0 Port 15 SD card slot Optional Rear panel components Figure 40 Rear panel components of SL165s G7 server system Item Description 1 Fan 6 2 Fan 5 3 Power Supply 1 4 Power Supply 2 5 Power Supply 3 6 Fan 2 7 Fan 1 8 Fan 3 9 Fan 4 10 Power blank 11 Chassis UID 12 SLAPM SL Advanced Power Manager connector ...

Page 58: ... slot 3 U1 Processor 1 4 J11 Mgmt card connector 5 J110 DIMM slot 12 for processor 1 6 J103 DIMM slot 1 for processor 1 7 J210 DIMM slot 12 for processor 2 8 U2 Processor 2 9 J54 4 pin power connector 10 J52 24 pin power connector 11 J61 Fan connector 1 12 J62 Fan connector 2 13 J203 DIMM slot 1 for processor 14 J68 Backplane I2 C connector 15 J53 8 pin power connector 16 J63 J64 Fan connectors 3 ...

Page 59: ...t to remove an installed TPM from the system board breaks or disfigures the TPM security rivet Upon locating a broken or disfigured rivet on an installed TPM administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data If you suspect a TPM board failure leave the TPM installed and remove the system board Contact an HP authorized ser...

Page 60: ...n problem diagnosis by indicating the status of system components and operations of the server Front panel LED indicators The front panel LED indicators allow constant monitoring of basic system functions while the server is operating Health LED Figure 42 Health LED Indicator location Table 5 Health LED indicator status Components Status Description Health LED indicator for Node 1 Red Blinking Cri...

Page 61: ...o system power off Health LED indicator for Node 3 Red Blinking Critical system failure detected Amber Blinking System degrade Green System in on and no failure detected Off System is off and there is no failure prior to system power off Health LED indicator for Node 4 Red Blinking Critical system failure detected Amber Blinking System degrade Green System in on and no failure detected Off System ...

Page 62: ...g a GbE link Off No connection UID LED Figure 44 UID LED indicator location Table 7 UID LED indicator status Components Status Descriptions UID LED indicator for Node 1 Blue Identification Blue Blinking System is being remotely managed Off Off UID LED indicator for Node 2 Blue Identification Blue Blinking System is being remotely managed Off Off UID LED indicator for Node 3 Blue Identification Blu...

Page 63: ...he server is operating normally Steady Amber The server is system off or in hibernation with A C power Off The server is system off without A C power Power LED indicator for Node 2 Steady green The server is operating normally Steady Amber The server is system off or in hibernation with A C power Off The server is system off without A C power Power LED indicator for Node 3 Steady green The server ...

Page 64: ...off or in hibernation with A C power Off The server is system off without A C power Rear panel LED indicators Rear Panel UID indicator status Figure 46 UID LED indicator location Table 9 UID LED indicator status Components Status Descriptions UID LED indicator for system Blue Identification Blue Blinking System is being remotely managed Off Off ...

Page 65: ...uch as serial console redirection PXE boot and much more Initialize hardware at boot up using POST routines During power on or warm reset the BIOS perform Power on Self Test POST routines to test system components to allocate resource for various hardware devices and to prepare the system to boot to various operating systems BIOS Setup Utility The HP server BIOS Setup Utility is used to configure ...

Page 66: ... out parameters are not user configurable for one of the following reasons The field value is auto configured or auto detected The field value is informational only The field is password protected Enter To select a field value or display a submenu screen Displays more option for items marked with Esc If you press this key On one of the primary menu screens the Exit menu displays On a submenu scree...

Page 67: ...general help message box Setup Utility Menu Bar The BIOS Setup Utility provides a menu bar with the menu selections The menu bar choices are described in the topics below Main Menu Figure 48 Main menu of BIOS Setup Utility Use this menu to set the system time and date and configure of the following items ...

Page 68: ...ss F9 key to restore the default settings CPU Configuration You can use this screen to select options for the CPU Configuration Settings Use the up and down Arrow keys to select an item Use the Plus and Minus keys to change the value of the selected option A description of the selected item appears on the right side of the screen The settings are described on the following pages SATA Configuration...

Page 69: ...e the up and down Arrow keys to select an item Use the plus and minus keys to change the value of the selected option The settings are described on the following pages OnBoard Peripherals Configuration Configure the settings of onboard peripherals Virtual Floppy Enabled or Disable Virtual Floppy Power Efficiency Mode Impact groups as CPU Configuration CPU Bridge Configuration PCI Express Configura...

Page 70: ...lay CPU temperature ambient temperature CPU fan speed system fan speed chassis fan speed These items cannot be changed by the user Watchdog Configuration Select Watchdog Configuration in the left frame of the screen and press enter to go to the submenu for that item That will display POST Watchdog Timer Action BMC Watch Dog Time Out you can change the default value Serial Port Configuration Select...

Page 71: ...o access the related submenu For details on the submenu options see the Boot Settings Configuration submenu section Boot Device Priority Use this screen to specify the order in which the system checks for a boot device Hard Disk Drives Use this screen to specify the boot sequence from the available devices USB Device Boot Priority Use this screen to control the latest added USB Functions by settin...

Page 72: ...visor Password Display if a supervisor password is Set or Not Change Supervisor Password Allows you to access and change all settings in the Setup Utility The supervisor password allows you to configure access for system users To set a new supervisor password 1 In the Security screen select a set password field Change Supervisor Password and then press Enter 2 Type a new password in the Enter New ...

Page 73: ...have made and exit the BIOS Setup Utility You can also press F10 key Discard Changes and Exit Exit the BIOS Setup Utility without saving the changes you have made You can also press Esc key Discard Changes Discard any changes you have made You can also press F7 key Restore Default Setting Restore the default settings for all BIOS setup fields BIOS Update Perform the steps below to update BIOS 1 Do...

Page 74: ...Set time date and other system values 9 Press F10 to close the Setup Utility NOTE Clearing CMOS restore all system configurations and password default settings Power on Self Test POST Before you can use a server all devices must be tested and initialized and the operating system must be bootstrapped to the memory This is referred to as Power on Self Test or POST POST is a series of diagnostic test...

Page 75: ...orrupted 613 Controller Operational Firmware Corrupted 620 Non Redundant Fan Failure or Missing 621 Redundant Fan Configuration One Fan Failure or Missing 622 Redundant Fan Configuration Multiple Fans Failure or Missing 623 Temperature Violation Detected Waiting 5 minutes for system to cool Press ESC Key to resume booting without waiting for the system to cool Warning Pressing ESC is NOT recommend...

Page 76: ...un displays error messages or emits beep codes If the POST failure is during a routine boot up check the following All external cables and power cables should be firmly plugged in The power outlet to the server should be connected and works correctly The server and monitor are both turned on The bicolour status LED indicator on the front panel must be lit up green The monitor s contrast and bright...

Page 77: ...pset ATI SR5670 ATI SP5100 Hardware monitoring device IPMI 2 0 compliant with LO100 Gigabit Ethernet controller Intel 82576EB Memory controller Integrated with AMD processor SATA and IDE controllers ATI SP5100 Embedded video controller VGA core integrated into LO100 I O subsystem X16 PCIE X16 Riser X4 PCIE X4 riser Memory 24 REG DDR3 800 1066 1333 MHz DIMM slots with ECC Support RDIMM and UDIMM De...

Page 78: ...tform ATX Advanced Technology Extended System board dimension 330 304 8 mm Server dimensions Rack 448W x 177H x 910L mm Server weight Full loading one chassis four tray with all memories LFF hard drives power supplies Fans and processors installed 68 9 kg Table 14 Environmental Specifications Item Description Temperature Operating Non operating Storage 0 to 40 30 to 65 30 to 65 Relative humidity O...

Page 79: ... voltage 90 VAC to 264 VAC 180 VAC to 300 VAC Only for 500W power supply 100 VAC to 120 VAC 200 VAC to 240 VAC 277 VAC Only for 500W power supply Line frequency 47Hz 63Hz Rated input current For 750W power supply 100V 240V 9 0 4 5A For 750W power supply high efficiency 100V 240V 9 0 405A For 1200W power supply 100V 9 4A 110V 120V 9 9A 200V 240V 7 8A For 1200W power supply high efficiency 100V 9 3A...

Page 80: ... panel spare part number 16 front panel components 56 H hard drive removing 34 hardware configuration BBWC 48 CPU DIMM Air Baffle 47 hard drives 33 memory 42 PCI expansion cards 45 power supply unit 52 processor 37 references 26 system battery 49 system fan 53 Hardware configuration tools 26 hardware specifications I O ports 77 LAN controller 77 memory 77 power supply unit 78 processor socket 77 p...

Page 81: ...POST related troubleshooting 76 recoverable POST errors 75 processor installing 40 removing 39 processor socket specification 77 PSU removing 52 replacement warnings 52 type 78 R rear panel components 57 S server dimensions rack 78 server warnings and cautions 27 SL165s chassis spare part number 16 SL165s system tray spare part number 16 storage controller 77 symbols on equipment 28 system battery...

Reviews: