Specifications 97
Specifications
Environmental specifications
Specification
Value
Temperature range*
Operating
10
°
C to 35
°
C (50
°
F to 95
°
F)
Shipping
-40
°
C to 70
°
C (-40
°
F to 158
°
F)
Maximum wet bulb temperature 28
°
C (82.4
°
F)
Relative humidity
(noncondensing)**
Operating
10% to 90%
Non-operating
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 kPa.
Mechanical specifications
Specification
Value
Dimension
Height (without tower feet)
44.45 cm (17.50 in)
Height (with tower feet)
46.70 cm (18.38 in)
Depth (with tower bezel)
60.00 cm (23.60 in)
Width
22.00 cm (8.66 in)
Weight (no drives installed)
27.22 kg (60.00 lb)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
•
HP ProLiant 1200 W Power Supply
Specification
Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
10 A at 100 VAC
4.9 A at 200 VAC
All manuals and user guides at all-guides.com
Summary of Contents for PROLIANT ML350 G6
Page 12: ...Customer self repair 12 All manuals and user guides at all guides com ...
Page 13: ...Customer self repair 13 All manuals and user guides at all guides com ...
Page 14: ...Customer self repair 14 All manuals and user guides at all guides com ...
Page 15: ...Customer self repair 15 All manuals and user guides at all guides com ...
Page 19: ...Illustrated parts catalog 19 All manuals and user guides at all guides com ...