Removal and replacement procedures 40
2.
Install the SFF hard drive cage into the server.
3.
Connect all cables to the spare hard drive cage.
CAUTION:
Always populate each media bay with either a device or a blank. Proper airflow can
only be maintained when the bays are populated. Unpopulated drive bays can lead to improper
cooling and thermal damage.
4.
Install any hard drives or blanks.
5.
Install the access panel.
6.
Do one of the following:
o
Close or install the tower bezel, as needed.
o
Slide the server back into the rack.
7.
Power up the server.
Optional two-bay LFF hard drive cage
To remove the component:
1.
Power down the server (on page
27
).
2.
Do one of the following:
o
Open or remove the tower bezel, as needed ("
Front bezel
" on page
29
).
o
Extend the server from the rack.
3.
Place the tower server on its side.
4.
Remove the access panel ("
Access panel
" on page
30
).
5.
Remove all hard drives ("
SAS/SATA hard drive
" on page
37
).
6.
Disconnect all cables from the rear of the hard drive cage.
NOTE:
Remove the shipping screw, if installed, before removing the hard drive cage.
All manuals and user guides at all-guides.com
Summary of Contents for PROLIANT ML350 G6
Page 12: ...Customer self repair 12 All manuals and user guides at all guides com ...
Page 13: ...Customer self repair 13 All manuals and user guides at all guides com ...
Page 14: ...Customer self repair 14 All manuals and user guides at all guides com ...
Page 15: ...Customer self repair 15 All manuals and user guides at all guides com ...
Page 19: ...Illustrated parts catalog 19 All manuals and user guides at all guides com ...