Removal and replacement procedures 41
7.
Remove the hard drive cage.
To replace the component:
1.
Slide the spare hard drive cage about three-fourths of the way into the bay, leaving room to connect
cables at the back of the drive cage.
2.
Connect all cables to the spare hard drive cage.
3.
Slide the optional hard drive cage fully into the bay until it clicks.
CAUTION:
Always populate each media bay with either a device or a blank. Proper airflow can
only be maintained when the bays are populated. Unpopulated drive bays can lead to improper
cooling and thermal damage.
4.
Install any hard drives or blanks.
5.
Install the access panel.
6.
Do one of the following:
o
Close or install the tower bezel, as needed.