Diagnostic tools 80
0251: System CMOS checksum bad – Default configuration used
In some cases an error message may include recommendations for troubleshooting or require that you
press the
Enter
key to display recommendations. Follow the instructions on the screen.
The next table lists the most common POST error messages with their corresponding troubleshooting
recommendation. It is recommended that you correct the error before proceeding, even if the server
appears to boot successfully.
If your system displays one of the messages marked below with an asterisk (
*
), write down the code
and message and contact your HP Customer Support provider.
Error code
Error message
Corrective action/description
000
Timer Error
Indicates an error while programming the
count register of channel 2 of the 8254 timer.
This might indicate an issue with system
hardware and requires repairing the system
board.
003
CMOS Battery Low
CMOS Battery is low. This message usually
indicates that the CMOS battery needs to be
replaced. It might also appear when the users
intentionally discharge the CMOS battery
004
CMOS Settings Wrong
CMOS settings are invalid. This error can be
resolved by using F9 to load optimal default
in the Setup Utility
008
Unlock Keyboard
PS2 keyboard is locked. User must unlock the
keyboard to continue the BIOS POST.
010
KBC BAT Test failed
The bat test on keyboard controller failed
011
CMOS Memory Size Wrong
The base memory (memory below 1MB) size
that is reported in the CMOS (offset 15h)
mismatches with the actual size detected. This
condition may occur when the hole is set at
512K base memory or when CMOS is
corrupted.
00C
RAM R/W test failed
This message appears by the AMI BIOS8
when the RAM read/write test fails.
00D
Uncorrectable Memory ECC Error! If DIMM occur Uncorrectable Memory ECC
Error!, this message will appear on POST
.
012
CMOS Date/Time Not Set
The CMOS date and/or time are invalid. This
error can be resolved by readjusting the
system time in the Setup Utility.
015
Fan Missing!
If system fan is not installed or failed, the
system will display this message and
shutdown in minutes.
016
System board temperature out of
range
If system detects system board temperature
sensor over heat, this message will appear.
Summary of Contents for ProLiant MicroServer
Page 12: ...Customer self repair 12 ...
Page 13: ...Customer self repair 13 ...
Page 14: ...Customer self repair 14 ...
Page 15: ...Customer self repair 15 ...
Page 16: ...Illustrated parts catalog 16 Illustrated parts catalog Mechanical components ...
Page 20: ...Illustrated parts catalog 20 ...
Page 21: ...Illustrated parts catalog 21 System components ...
Page 38: ...Removal and replacement procedures 38 6 Perform the post installation procedure ...
Page 50: ...Removal and replacement procedures 50 5 Perform the post installation procedure ...
Page 66: ...Diagnostic tools 66 5 Click Browse to select folder and then click Next 6 Click Next ...
Page 67: ...Diagnostic tools 67 7 Click Install 8 Click Finish ...
Page 70: ...Diagnostic tools 70 13 Click options Enable or Disable to change Write cache and NCQ status ...