12
HP ProLiant DL580 Generation 3 Server User Guide
Item Description
Status
5
NIC 2 link/activity LED
Green = Linked to network
Flashing green = Linked with activity on the network
Off = No network connection
6
Power on/Standby button
and LED
Amber = System has AC power and is in standby mode
Green = System has AC power and is turned on
Off = System has no AC power
Memory board components and LEDs
Error indicators remain illuminated when the system is powered off so that the
status of the LEDs can still be seen. This behavior matches the behavior of all the
other error indicators in the server.
The indicators are only cleared in the following situations:
•
If the locking switch is locked after the board is reinstalled
•
If the server is rebooted
•
If the board is removed from the server
CAUTION: When the memory board locking switch is unlocked in
a mode that does not support hot-add or hot-replace capabilities, audio
alarms and visual alerts occur. Removing the memory board at this
point causes server failure.
To end the audio alarms and visual alerts, move the memory board
locking switch back to the locked position. This action does not result in
data corruption or server failure.
Summary of Contents for ProLiant DL580 Generation 3
Page 8: ......
Page 36: ......
Page 46: ...46 HP ProLiant DL580 Generation 3 Server User Guide ...
Page 114: ......
Page 122: ......
Page 152: ...152 HP ProLiant DL580 Generation 3 Server User Guide ...
Page 154: ...154 HP ProLiant DL580 Generation 3 Server User Guide ...
Page 157: ...Troubleshooting 157 ...
Page 159: ...Troubleshooting 159 ...
Page 161: ...Troubleshooting 161 ...
Page 162: ...162 HP ProLiant DL580 Generation 3 Server User Guide ...
Page 165: ...Troubleshooting 165 ...
Page 170: ......
Page 180: ......