Specifications 86
Rated input power
312 W; 1,066 Btu/hr
Power supply output
—
Efficiency
80%
Maximum peak power
250 W
HP 300 W Integrated Power Supply
Specification
Value
Input requirements
—
Rated input voltage
100 V AC to 127 V AC
200 V AC to 240 V AC
Rated input frequency
50 Hz–60 Hz
Rated input current
6 A max at 100 V AC
3 A max at 200 V AC
Rated input power
600 W
Power supply output
—
Efficiency
80%
Maximum peak power
350 W (duration less 10 sec at 25°C)
HP 750 W CS -48 V DC Power Supply (94% efficiency)
Specification
Value
Input requirements
—
Rated input voltage
-36 V DC to -72 V DC
-48 V DC nominal input
Rated input current
23 A at -36 V DC input
17 A at -48 V DC input, nominal
input
11 A at -72 V DC input
Rated input power (W)
815 W at -36 V DC input
805 W at -48 V DC input, nominal
input
795 W at -72 V DC input
Rated input power (Btus per
hour)
2780 at -36 V DC input
2740 at -48 V DC input, nominal
input
2720 at -72 V DC input
Power supply output
—
Rated steady-state power (W) 750 W
Maximum peak power (W)
750 W
CAUTION:
This equipment is designed to permit the connection of the earthed conductor of the
DC supply circuit to the earthing conductor at the equipment.
If this connection is made, all of the following must be met:
•
This equipment must be connected directly to the DC supply system earthing electrode
conductor or to a bonding jumper from an earthing terminal bar or bus to which the DC supply
system earthing electrode conductor is connected.