QuickSpecs
HPE ProLiant DL20 Generation9 (Gen9)
Technical Specifications
Page 44
System Unit
Dimensions
(H x W x D)
4 SFF - 1.70 x 17.11 x 15.05 inches (4.32 x 43.46 x 38.22 cm)
2 LFF - 1.70 x 17.11 x 15.05 inches (4.32 x 43.46 x 38.22 cm)
NOTE:
Depth of the chassis from rear to bezel is 15.5".
Weight
(approximate)
Non hot Plug 2
LFF fully loaded
(all hard drives,
power supplies,
and processors
installed)
17.37Ib (7.88kg)
Hot Plug 2LFF fully
loaded
(one hard drive,
power supply, and
processor
installed)
17.41lb (7.9kg)
4 SFF Fully loaded
19.18lb (8.7kg)
290W Non-hot Plug Power Supply
Input
Requirements
Range Input
Voltage
100 to 240 VAC
Rated Input
Current
5.5 A max (at 100 VAC)
Rated Input
Frequency
50 to 60 Hz
Rated Input
Power
550 W (at 100 VAC)
BTU Rating
Maximum
1130 BTU per hr (at 115 VAC)
1126 BTU per hr (at 230 VAC)
Power
Specifications
To review typical system power ratings use the Power Advisor which is available via
the online tool located at URL:
http://www.hp.com/go/proliant-energy-efficient
or
http://www.hp.com/go/hppoweradvisor
- Click on the system of interest.
Example: DL20 Gen9- Follow the instructions of the next screens.
Power Supply
Output
Rated Steady-
State Power
290 W Max
Maximum Peak
Power
366 W within 10 seconds
System Inlet
Temperature
Standard
Operating Support
10° to 35°C (50° to 95°F) at sea level with an altitude derating of
1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level
to a maximum of 3050 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 20°C/hr (36°F/hr). The
upper limit and rate of change may be limited by the type and
number of options installed. System performance during
standard operating support may be reduced if operating with a
fan fault or above 30°C (86°F).
Extended Ambient
Operating Support
For approved hardware configurations, the supported system
inlet range is extended to be: 5° to 10°C (41° to 50°F) and 35° to
40°C (95° to 104°F) at sea level with an altitude derating of