Removal and replacement procedures 59
6.
Install the heatsink:
a.
Using the guide pin on the processor backplate, position the heatsink.
b.
Tighten one pair of diagonally opposite screws halfway, and then tighten the other pair of screws.
c.
Finish the installation by completely tightening the screws in the same sequence.
7.
Install the processor air baffle.
8.
Install the access panel.
9.
Do one of the following:
o
Slide the server into the rack.
o
Install the server into the rack.
10.
Connect each power cord to the server.
11.
Connect each power cord to the power source.
12.
Power up the server.
System board
To remove the component:
1.
Power down the server (on page
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Remove the server from the rack (on page
4.
Remove the access panel ("
" on page
5.
Remove the processor air baffle ("
" on page
6.
If installed, remove the FBWC capacitor pack ("
" on page
CAUTION:
To prevent damage to the server or expansion boards, power down the server and
remove all AC power cords before removing or installing the PCI riser cage.
Summary of Contents for ProLiant DL160 Gen8
Page 12: ...Customer self repair 12 ...
Page 13: ...Customer self repair 13 ...
Page 14: ...Customer self repair 14 ...
Page 17: ...Illustrated parts catalog 17 ...
Page 23: ...Illustrated parts catalog 23 ...