System Unit
System Unit
System Unit
System Unit
Dimensions
Dimensions
Dimensions
Dimensions (H x W x D)
(with bezel)
3.44 x 17.64 x 28.91 in (8.74 x 44.81 x 73.43 cm)
Weight
Weight
Weight
Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
72.00 lb (32.7 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
40.00 lb (18.2 kg)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
Rated Line Voltage
90 to 140 VAC
180 to 264 VAC
Rated Input Current
7.31A at 115VAC
3.6A at 230VAC
Rated Input Frequency
47 to 63 Hz
Rated Input Power
855W (at 100 VAC),
840.72W (at 200 VAC)
Power Specifications
Power Specifications
Power Specifications
Power Specifications
NOTE:
NOTE:
NOTE:
NOTE: To review typical system power ratings use the HP Power Advisor
which is available online located at url:
www.hp.com/go/proliant-energy-
efficient
or
www.hp.com/go/hppoweradvisor
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
(per power supply)
Rated Steady-State Power 653.10W (at 100 VAC),
653.08W (at 200 VAC)
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
50° to 95° F (10° to 35° C) at sea level with an
altitude derating of 1.8°F per every 1000 ft
(1.0°C per every 305 m) above sea level to a
maximum of 10,000 ft (3050 m), no direct
sustained sunlight. Maximum rate of change is
18°F/hr (10°C/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 86°F (30°C).
Non-operating
40° to 140° F (-40° to 60° C)
Maximum rate of change is 36°F/hr (20°C/hr).
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Operating
10% to 85% relative humidity (Rh), 82.4°F
(28°C) maximum wet bulb temperature, non-
condensing.
Non-operating
10% to 95% relative humidity (Rh), 101.7°F
(38.7°C) maximum wet bulb temperature, non-
condensing.
Altitude
Altitude
Altitude
Altitude
Operating
10,000 ft (3050 m). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 1500
ft/min (457 m/min).
Non-operating
30,000 ft (9144 m). Maximum allowable
altitude change rate is 1500 ft/min (457 m/min).
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
Listed are the declared A-Weighted sound power levels (L
WAd
) and declared
QuickSpecs
HP ProLiant DL1000 Multi Node Server
HP ProLiant DL1000 Multi Node Server
HP ProLiant DL1000 Multi Node Server
HP ProLiant DL1000 Multi Node Server
Technical Specifications
DA - 13309 Canada — Version 31 — April 8, 2011