HP Monitored Power Distribution Unit: Half Rack Version
HP Monitored Power Distribution Unit: Half Rack Version
HP Monitored Power Distribution Unit: Half Rack Version
HP Monitored Power Distribution Unit: Half Rack Version
HP 4.9 kVA S124 Monitored PDU- single input, 1Ø, 24A
AF914A
HP Monitored Power Distribution Unit: Full Rack Version
HP Monitored Power Distribution Unit: Full Rack Version
HP Monitored Power Distribution Unit: Full Rack Version
HP Monitored Power Distribution Unit: Full Rack Version
HP 8.6 kVA S1324 Monitored PDU- single input, 3Ø, 24A
AF504A
HP 8.3 S1140 Monitored PDU- single input, 1Ø, 40A
AF506A
NOTE:
NOTE:
NOTE:
NOTE: Please see the following QuickSpecs for additional information:
http://h18000.www1.hp.com/products/quickspecs/12118_ca/12118_ca.html
Modular Power Distribution Units 1U/0U (Up to 32 outlets)
Modular Power Distribution Units 1U/0U (Up to 32 outlets)
Modular Power Distribution Units 1U/0U (Up to 32 outlets)
Modular Power Distribution Units 1U/0U (Up to 32 outlets)
NOTE:
NOTE:
NOTE:
NOTE: 1U/0U mounting brackets shipped with the unit (optimized for 10000 and
9000 series racks).
HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC)
252663-D72
8.3kVA Model - mPDU, 40A, High (power cord attached)
252663-D73
HP Modular Power Distribution Units (mPDU), High Volt Model, 16A (200-240 VAC)
NOTE:
NOTE:
NOTE:
NOTE: This PDU has a detachable input power cord and allows for adaptability to
country specific power requirements.
252663-B24
NOTE:
NOTE:
NOTE:
NOTE: Please see the following QuickSpecs for additional options including shorter
jumper cables and country specific power cords:
http://h18000.www1.hp.com/products/quickspecs/11041_ca/11041_ca.html
NOTE:
NOTE:
NOTE:
NOTE: For additional information on HP Power Distribution Units including
accessories please go to:
www.hp.com/go/pdu
.
HP Rack Series
HP Rack Series
HP Rack Series
HP Rack Series
HP Rack 10000 G2 Series
HP Rack 10000 G2 Series
HP Rack 10000 G2 Series
HP Rack 10000 G2 Series (Carbon/Graphite Metallic)
HP 10642 G2 Pallet Universal Rack
AF001A
HP 10642 G2 Shock Universal Rack
AF002A
NOTE:
NOTE:
NOTE:
NOTE: It is mandatory to use a shock pallet when shipping racks with equipment
installed.
NOTE:
NOTE:
NOTE:
NOTE: Please see the QuickSpecs for additional information:
http://h18000.www1.hp.com/products/quickspecs/12402_ca/12402_ca.html
NOTE:
NOTE:
NOTE:
NOTE: For additional information regarding Rack Cabinets, please see the following
URL:
http://www.hp.com/go/rackandpower
.
NOTE:
NOTE:
NOTE:
NOTE: The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The 10000 G2 Series Racks
provide enhanced airflow for maximum cooling, allowing these racks to be fully
loaded with servers using the latest processors.
CAUTION:
CAUTION:
CAUTION:
CAUTION: If a third-party rack is used, observe the following additional requirements
to ensure adequate airflow and to prevent damage to the equipment: Front and rear
doors: If your 42U server rack includes closing front and rear doors, you must allow
830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to
permit adequate airflow (equivalent to the required 64 percent open area for
ventilation). Side: The clearance between the installed rack component and the side
panels of the rack must be a minimum of 2.75 inches (7 cm).
CAUTION:
CAUTION:
CAUTION:
CAUTION: Always use blanking panels to fill all remaining empty front panel U-
spaces in the rack. This arrangement ensures proper airflow. Using a rack without
blanking panels results in improper cooling that can lead to thermal damage.
QuickSpecs