Option
Option
Option
Option
Slots #
Slots #
Slots #
Slots #
Width
Width
Width
Width
*
1
PCI-Express
2.0
x8
x8
4
Full length,
full height
3.3 volts
2
PCI-Express
2.0
x8
x8
5
Full length,
half height
3.3 volts
3
PCI-Express
2.0
x8
x8
7
Low Profile
3.3 volts
Full-height PCIe Riser
Full-height PCIe Riser
Full-height PCIe Riser
Full-height PCIe Riser
Option
Option
Option
Option
(Standard in 2 Node BTO
Models)
Expansion
Expansion
Expansion
Expansion
Slots #
Slots #
Slots #
Slots #
Technology
Technology
Technology
Technology
Bus Width
Bus Width
Bus Width
Bus Width
**
Connector
Connector
Connector
Connector
Width
Width
Width
Width
*
Bus Number
Bus Number
Bus Number
Bus Number
Form Factor
Form Factor
Form Factor
Form Factor
Notes
Notes
Notes
Notes
1
PCI-Express
2.0
x16
x16
4
Full length,
full height
3.3 volts
3
PCI-Express
2.0
x8
x8
6
Low Profile
3.3 volts
Half-height PCIe Riser
Half-height PCIe Riser
Half-height PCIe Riser
Half-height PCIe Riser
(Standard in 4 Node BTO
Models and with half-
height nodes)
Expansion
Expansion
Expansion
Expansion
Slots #
Slots #
Slots #
Slots #
Technology
Technology
Technology
Technology
Bus Width
Bus Width
Bus Width
Bus Width
**
Connector
Connector
Connector
Connector
Width
Width
Width
Width
*
Bus Number
Bus Number
Bus Number
Bus Number
Form Factor
Form Factor
Form Factor
Form Factor
Notes
Notes
Notes
Notes
1
PCI-Express
2.0
x16
x16
4
Low Profile
3.3 volts
* Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number.
** Indicates the number of physical electrical lanes running to the connector.
Storage Controller
Storage Controller
Storage Controller
Storage Controller
Non-Hot Plug SATA
Models
Embedded HP Smart Array Hot Plug Advanced Pack for B110i (RAID 0, 1,
10)
NOTE:
NOTE:
NOTE:
NOTE: Transfer rate: up to 3 Gb/s SATA
NOTE:
NOTE:
NOTE:
NOTE: To enable RAID on Embedded SATA (Windows and Linux only), use
the HP Smart Array B110i SATA Raid controller, To enable use of the B110i,
enter the ROM based setup utility(RBSU). The option for enabling RAID can
be found in the advanced section of the RBSU. For additional details
www.hp.com/go/SATARAID
. For RAID on Solaris, a Smart Array Controller
must be purchased.
Hot Plug SATA Models
Embedded HP Smart Array Hot Plug Advanced Pack for B110i (RAID 0, 1,
10)
NOTE:
NOTE:
NOTE:
NOTE: Transfer rate: up to 3Gb/s SATA
NOTE:
NOTE:
NOTE:
NOTE: The HP Smart Array B110i SATA Raid Hot Plug Advance Pack
provides the hot-plug and RAID support for the embedded SATA controller.
The Hot Plug Advance kit is a License to enable the RAID support on Hot
Plug models. It supports up to six 3G SATA hard disk drives. It will support a
maximum of two (2) logical drives. It supports Raid 0, 1 and 1+0. For
additional details
www.hp.com/go/SATARAID
Hot Plug SAS/SATA
Models
HP Smart Array Controller RAID 0,1,10, 5
NOTE:
NOTE:
NOTE:
NOTE: Transfer rate: up to 6GB/s SAS, 3Gb/s SATA
NOTE:
NOTE:
NOTE:
NOTE: SAS Upgrade: A HP Smart Array Controller is required for SAS HDD support. Transfer rate: 6.0
Gb/s SAS supported.
NOTE:
NOTE:
NOTE:
NOTE: When adding a Smart Array Controller to an 8 LFF SAS HDD configuration, a HP h1000 LFF
SAS CONTROLLER CABLE OPTION KIT (P/N 519503-B21) must be ordered to connect the Smart Array
Controller to the hard drive backplane. When a controller is added during a CTO buildup, the
appropriate cables are included and this kit is not required. This cable kit is only needed for BTO
configurations or if a CTO customer upgrades to a Smart Array Controller after initial purchase.
QuickSpecs
HP ProLiant DL1000 Multi Node Server
HP ProLiant DL1000 Multi Node Server
HP ProLiant DL1000 Multi Node Server
HP ProLiant DL1000 Multi Node Server
Standard Features
DA - 13309 Canada — Version 31 — April 8, 2011
Page 4