Removal and replacement procedures 25
3.
Remove the server blade.
4.
Place the server blade on a flat, level work surface.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
To prevent damage to electrical components, properly ground the server blade
before beginning any installation procedure. Improper grounding can cause ESD.
Access panel
To remove the component:
1.
Power down the server blade (on page
23
).
2.
Remove the server blade (on page
24
).
3.
Lift the access panel latch and slide the access panel to the rear.
4.
Remove the access panel.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
To prevent damage to electrical components, properly ground the server blade
before beginning any installation procedure. Improper grounding can cause ESD.
To replace the component:
1.
Place the access panel on top of the server blade with the hood latch open. Allow the panel to extend
past the rear of the server blade approximately 0.8 cm (0.2 in).
2.
Engage the anchoring pin with the corresponding hole in the latch.
3.
Push down on the hood latch. The access panel slides to a closed position.
Summary of Contents for ProLiant BL460c G7
Page 12: ...Customer self repair 12 ...
Page 13: ...Customer self repair 13 ...
Page 14: ...Customer self repair 14 ...
Page 15: ...Customer self repair 15 ...
Page 21: ...Illustrated parts catalog 21 ...