background image

Hot Plug SAS/SATA or Non-Hot Plug SATA Models

Front View:

Rear View:

1.

Access panel

1.

Power supply

2.

System fans

2.

Optional SD Card Reader

3.

Front-panel USB 2.0 ports

3.

Unit Identification LED (UID)

4.

Power switch/system status LEDs

4.

Two USB ports

5.

Standard 1st , 2nd , 3rd and 4th 3.5" hot-plug
SAS/SATA or non-hot plug SATA hard drive bays

5.

Optional Lights-Out 100 10/100Mbps port

6.

Optical drive bay

6.

Serial port

7.

Twenty Four DIMM Slots

7.

(2) RJ45 GbE LAN ports (3rd & 4th port)

8.

Slot 1:Full-length/Full height x16 PCI-Express Gen2 slot,
or
Slot 1: Half-length/Full height x16 PCI-Express Gen2
slot and
Slot 2: Low Profile x4 PCI-Express Gen2 slot (accepts
x8 cards, internal only)

8.

VGA port

9.

Two (2) AMD Opteron 6100 series processors

9.

(2) RJ45 GbE LAN ports (1st & 2nd port)

 

 

10.

Slot 1:Full-length/Full height x16 PCI-Express Gen2 slot,
or
Slot 1: Half-length/Full height x16 PCI-Express Gen2
slot and
Slot 2: Low Profile x4 PCI-Express Gen2 slot (accepts
x8 cards, internal only)

At A Glance

Introducing the HP ProLiant DL165G7, now available with the latest high performance Opteron Eight and Twelve Core
processors, 24 DDR3 memory DIMMs, 2 PCIe Gen2 slots, four NIC ports and an Easy Setup CD.

Processors

:

Supports up to two AMD Opteron™ 6000 series Eight and Twelve Core processors
Supports DirectConnect Architecture
Supports Power Now

Memory

:

Up to 256GB, using 2x8GB Dual-Rank and 1x16GB Quad-Rank PC3-8500R-7 DDR3 Registered (RDIMM)
memory per memory channel, operating at 800MHz in 24 slots. (See memory section for population rules)
Up to 192GB, using 8GB PC3-10600R or PC3-8500R DDR3 Registered (RDIMM) memory, operating at
800MHz when populated at 3 DIMMs per Channel in 24 slots.
Up to 64GB, using PC3-10600E DDR3 Unbuffered (UDIMM) memory, operating at 1066MHz when populated at
2 DIMMs per Channel in 16 slots.

Internal Drive Support

:

QuickSpecs

HP ProLiant DL165 Generation 7

Overview

DA - 13602   Worldwide QuickSpecs — Version 2 — 4.2.2010

Page 1

Summary of Contents for ProLiant DL165

Page 1: ... x16 PCI Express Gen2 slot and Slot 2 Low Profile x4 PCI Express Gen2 slot accepts x8 cards internal only At A Glance Introducing the HP ProLiant DL165G7 now available with the latest high performance Opteron Eight and Twelve Core processors 24 DDR3 memory DIMMs 2 PCIe Gen2 slots four NIC ports and an Easy Setup CD Processors Supports up to two AMD Opteron 6000 series Eight and Twelve Core process...

Page 2: ...ower Supply Non Hot Plug PFC Autoswitching Optional FIO high efficiency pluggable power supplies 750W Power Supply Form Factor Rack 1U Fixed mounting rails included with all models Deployment Serviceability HP ProLiant DL165 G7 models have tool less fixed rails which provide support for racks with round mounting holes and tool free support for racks with square mounting holes including Compaq HP 7...

Page 3: ...Opteron Processor Model 6174 2 2 GHz 12MB Level 3 Cache 80W NOTE Available through Configure To Order only See Factory Integration Models section for more details Upgradeability Upgradeable to two processors Chipset AMD Chipset SR5670 SP5100 Cache Memory Model Series 6000 12MB shared L3 Memory Protection Advanced ECC Memory One of the following depending on Model Type DDR3 Registered RDIMM or Unbu...

Page 4: ...taraid Cold Plug SATA Models HP Smart Array B110i SATA RAID Controller NOTE Supported on LFF models only Hot Plug SATA SAS HP Smart Array P410 Controller RAID 0 1 1 0 HP Smart Array P410 Controller 256 BBWC RAID 0 1 1 0 5 5 0 NOTE Transfer rate up to 3 Gb s SATA up to 6 Gb s SAS HP Smart Array B110i SATA RAID Controller NOTE Hot plug functionality requires the addition of a Smart Array Advanced Pa...

Page 5: ...Management Serial 1 Pointing Device Mouse 0 via USB only Graphics 1 Keyboard 0 via USB only USB 6 two front two internal two rear NOTE One optional internal USB connector is reserved for connection to the rear SD Card Reader 592710 B21 NOTE In order to connect a USB device internally the internal USB Cable G6 Kit must be used 536769 B21 NOTE Please see the following URL for additional information ...

Page 6: ...ing a Linux based management consoles See www hp com go ic linux HP Insight Control include one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates For more information about this service please visit http www hp com services insight Insight Control server deployment HP Insight Control server deploymen...

Page 7: ...y TPM deployed server and must be retained Misplacing or losing the key could result in data loss Server Power Cords One 6 Highline IEC IEC power cord ships standard NOTE HP ProLiant DL servers no longer ship standard with NEMA power cords 163719 002 that allow connection to 110V US wall outlets in a home or office ProLiant DL servers are primarily connected to PDU s in data center racks so they n...

Page 8: ...o prevent damage to the equipment Front and rear doors If your 42U server rack includes closing front and rear doors you must allow 5 350 sq cm 830 square inches of hole evenly distributed from top to bottom to permit adequate airflow equivalent to the required 64 percent open area for ventilation Side The clearance between the installed rack component and the side panels of the rack must be a min...

Page 9: ...re It also includes the 22 and smaller external monitors and tower UPS options up to 3kVA These items will be covered at the same service level and for the same coverage period as the server Coverage of UPS Battery is not included and standard warranty terms conditions apply For servers or storage systems installed within a rack service also covers all HP qualified rack options installed within th...

Page 10: ...ibility with the help of configuration tools Please visit the following URL to configure HPC Clusters with InfiniBand Gigabit Ethernet or Myrinet Interconnects http www hp com techservers clusters ucp index html HPC Interconnects InfiniBand PCI Express Generation 2 adapters Gigabit Ethernet Use embedded ports or optional 10GbE NICs 10 Gigabit Ethernet PCI Express Generation 2 QuickSpecs HP ProLian...

Page 11: ... Plug 3 5 SAS Hard Drives Maximum Optical Drive None ship standard Form Factor 1U HP DL165G7 6128 Hot Plug SAS SATA 590259 xx1 Processor s AMD Opteron Processor Model 6128 2 0 GHz 12MB Level 3 Cache 80W Cache Memory 12 MB shared L3 cache Memory 4GB 2 x 2GB PC3 10600R RDIMM Network Controller 2x HP NC362i Integrated Dual Port Gigabit Server Adapter Storage Controller HP Smart Array B110i Hard Drive...

Page 12: ...Country Code Key xx 00 U S xx 29 Japan xx 37 APD xx 42 Euro xx AA PRC QuickSpecs HP ProLiant DL165 Generation 7 Models DA 13602 Worldwide QuickSpecs Version 2 4 2 2010 Page 12 ...

Page 13: ...lot or Slot 1 HL FH x16 PCI Express Gen2 slot and Slot 2 HL LP x8 PCI Express Gen2 slot internal only HP Smart Array B110i SATA RAID Controller One Highline IEC Power Cord 4 Fixed Non Redundant Fans standard 6 Fixed N 1 Redundant Fans standard with addition of second processor Rack 1U 1 75 in 4 45 cm Tool less Fixed Rails Hot Plug Cold Plug Models HP DL165G7 LFF CTO Chassis 592226 B21 HP DL165G7 S...

Page 14: ...2Rx4 PC3 10600R 9 Kit 593907 B21 HP 4GB 1Rx4 PC3 10600R 9 Kit 593911 B21 HP 4GB 1Rx4 PC3L 10600R 9 Kit 604500 B21 HP 8GB 2Rx8 PC3 10600R 9 Kit 593913 B21 HP 8GB 2Rx4 PC3L 10600R 9 Kit 604502 B21 HP 16GB 4Rx4 PC3 8500R 7 Kit 593915 B21 Unbuffered with ECC DIMMs UDIMMs HP 2GB 2Rx8 PC3 10600E 9 Kit 593921 B21 HP 4GB 2Rx8 PC3 10600E 9 Kit 593923 B21 NOTE All DDR3 memory option kits consist of one DIMM...

Page 15: ...Plug Midline 1y Wty Hard Drive 458939 B21 HP Storage Controllers NOTE With the HP Smart Array P410 Controller the addition of the battery backed cache upgrade enables BBWC RAID 5 5 0 array expansion logical drive extension RAID migration and stripe size migration In order to upgrade to RAID 6 at least 256MB Cache and a Battery is required in addition to the Smart Array Advanced Pack license P N 51...

Page 16: ...oller the addition of the battery backed cache upgrade enables BBWC RAID 5 5 0 array expansion logical drive extension RAID migration and stripe size migration In order to upgrade to RAID 6 at least 256MB Cache and a Battery is required in addition to the Smart Array Advanced Pack license P N 516471 B21 NOTE To use the internal only PCI e slot when purchasing the Hot Plug CTO Chassis a HP Smart Ar...

Page 17: ...B21 HP 4GB 2Rx8 PC3 10600E 9 Kit 593923 B21 NOTE PC3L is a low voltage memory HP Optical Drives DVD ROM Drive Optical Drive 481045 B21 DVD RW Drive Optical Drive 481047 B21 HP Hard Drives NOTE The components of a storage subsystem e g the drive the HBA controller and the server backplane should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable ...

Page 18: ...13415_div 13415_div html Worldwide SAS Hot Plug LFF 3 5 inch Enterprise ENT Drives HP 600GB 6G SAS 15K LFF 3 5 inch Dual Port Enterprise 3yr Warranty Hard Drive 516828 B21 HP 450GB 6G SAS 15K LFF 3 5 inch Dual Port Enterprise 3yr Warranty Hard Drive 516816 B21 HP 450GB 3G SAS 15K LFF 3 5 inch Dual Port Enterprise 3yr Warranty Hard Drive 454232 B21 HP 300GB 6G SAS 15K LFF 3 5 inch Dual Port Enterpr...

Page 19: ...Attach Cable DAC for copper environments or fiber transceivers and cables for fiber optic environments must be purchased separately 468332 B21 HP NC550SFP Dual Port 10GbE Server Adapter NOTE A minimum of two Gigabytes 2 GB of server memory is required per each NC550SFP adapter NOTE Direct Attach Cable DAC for copper environments or fiber transceivers and cables for fiber optic environments must be...

Page 20: ...chnical Support and Updates T9082AAE HP Insight Control server deployment 1 Server License including 1 year 24x7 Technical Support and Updates 452151 B21 NOTE Licenses ship without media The Insight Control Media Kit can be ordered separately or can be downloaded at http www hp com go insightupdates NOTE Electronic licenses can be used to purchase multiple licenses with a single activation key and...

Page 21: ...h Backed Write Cache 534916 B21 HP Smart Array Advanced Pack No Media 1 Server license including 1yr 24x7 Technical Support 516471 B21 NOTE This part number can be used to purchase a single license or to order multiple licenses with a single activation key Customers will receive a license entitlement certificate via e mail The license entitlement certificate must be redeemed online or via fax in o...

Page 22: ... 1U USB Rack Mount Kit with one DAT 320 USB Tape Drive AP835A HP StorageWorks DAT 320 SAS Internal Tape Drive NOTE For installation into 1U SAS Rack Mount Kit AE459B or 3U SAS Rack Mount Kit AG576B No peripheral bay available for installation into the server Connection using the HP SC44Ge SAS Host Bus Adapter 416096 B21 recommended AJ830A HP StorageWorks LTO 2 Ultrium 448 SAS Internal Tape Drive N...

Page 23: ...t A8007A No peripheral bay available for drive installation into the server 500GB of disk capacity per data cartridge AJ934A HP StorageWorks RDX750 Internal Removable Disk Backup System NOTE For installation into 1U USB Rack Mount Kit A8007A No peripheral bay available for drive installation into the server 750GB of disk capacity per data cartridge AW577A HP StorageWorks Options StorageWorks Fibre...

Page 24: ...nformation http h18000 www1 hp com products quickspecs 13160_div 13160_div html Worldwide NOTE For additional information on all HP Uninterruptible Power Systems and accessories please go to www hp com products ups Worldwide NOTE For additional information on sizing your server please reference http www upssizer com HP Rack Series HP Rack 10000 G2 Series Carbon Graphite Metallic HP Universal Rack ...

Page 25: ...6 KVM IP Console Switch G2 with Virtual Media and CAC AF621A 4x1Ex32 KVM IP Console Switch G2 with Virtual Media and CAC AF622A NOTE For additional information regarding KVM switches Serial Console servers rack mount monitors keyboards and all related options please see the following URL http www hp com go kvm HP USB and SD Options HP USB P S2 Mouse DC369A HP USB 04 Standard Keyboard DT528A ABA HP...

Page 26: ...apacity between all installed processors It is not required but it is recommended to load the channels similarly if possible You can only have up to eight 8 ranks installed per channel Mixing DIMM speeds is allowed but the system processor speed rules always override the DIMM capabilities If you do mix DIMM speeds the memory bus will default to the minimum clock rate of all DIMMs in the system eve...

Page 27: ...1333 1066 1066 n a n a n a This capacity is achieved by loading 1 16GB in center socket and remaining sockets with 8GB DIMMs DIMM slot and configuration diagrams Basic memory slot population diagram Population order start with A first B second C third etc 24 DIMM SLOTS 12 per CPU node CPU1 CPU2 slot population order slot population order Chnl 1 1 A 1 A Chnl 1 2 I 2 I 3 E 3 E Chnl 2 4 C 4 C Chnl 2 ...

Page 28: ...Kit 604500 B21 HP 8GB 2Rx8 PC3 10600R 9 Kit 593913 B21 HP 8GB 2Rx4 PC3L 10600R 9 Kit 604502 B21 HP 16GB 4Rx4 PC3 8500R 7 Kit 593915 B21 Unbuffered with ECC DIMMs UDIMMs HP 2GB 2Rx8 PC3 10600E 9 Kit 593921 B21 HP 4GB 2Rx8 PC3 10600E 9 Kit 593923 B21 NOTE PC3L is a low voltage memory QuickSpecs HP ProLiant DL165 Generation 7 Memory DA 13602 Worldwide QuickSpecs Version 2 4 2 2010 Page 28 ...

Page 29: ...Position Supported Controller 2TB 3G SATA 7 2K 1TB 3G SATA 7 2K 750GB 3G SATA 7 2K 500GB 3GSATA 7 2K 250GB 3G SATA 7 2K Up to 4 1 4 HP Smart Array P212 Controller HP Smart Array P410 Controller HP Smart Array P812 Controller SATA Hot Plug LFF 3 5 inch Midline MDL Drives Quantity Supported Position Supported Controller 2TB 3G SATA 7 2K 1TB 3G SATA 7 2K 750GB 3G SATA 7 2K 500GB 3G SATA 7 2K 250GB 3G...

Page 30: ...S 7 2K 1TB 6G SAS 7 2K 1TB 3G SAS 7 2K 750 3G SAS 7 2K Up to 4 1 4 HP Smart Array P212 Controller HP Smart Array P410 Controller HP Smart Array P812 Controller SAS Hot Plug SFF 2 5 inch Enterprise ENT Drives Quantity Supported Position Supported Controller 300GB 6G SAS 10K 300GB 3G SAS 10K 146GB 6G SAS 15K 146GB 3G SAS 15K 146GB 6G SAS 10K 146GB 3G SAS 10K 72GB 6G SAS 15K 72GB 3G SAS 10K Up to 8 1...

Page 31: ...rageWorks USB Tape Drives External DAT 40 DAT 72 DAT 160 DAT 320 1U USB Rack Mount Kit External USB 2 0 Port N A HP StorageWorks SAS Tape Drives External DAT 160 DAT 320 LTO 2 Ultrium 448 LTO 3 Ultrium 920 LTO 4 Ultrium 1760 LTO 4 Ultrium 1840 LTO 5 Ultrium 3000 LTO 5 Ultrium 3280 1U Rack Mount Kit 3U Rack Mount Kit External HP Smart Array P212 SAS controller Please check the full compatibility in...

Page 32: ...QuickSpecs HP StorageWorks USB RDX Removable Disk Backup System External RDX160 RDX320 RDX500 RDX750 External USB 2 0 port N A HP StorageWorks D2D Backup Systems iSCSI D2D2500i D2D4000i Rack Mount Embedded Network Controller If the server requires a hardware iSCSI initiator the QLogic QLA4050 Host Bus Adapter is recommended HP StorageWorks D2D Backup Systems Fibre Channel D2D4000fc Rack Mount Dire...

Page 33: ...quency Range Nominal Hz 50 60 Nominal Input Voltage Vrms 100 120 200 208 220 230 240 Max Rated Output Wattage Rating 750 750 750 750 750 750 750 Nominal Input Current A rms 8 9 7 4 4 3 4 1 3 9 3 7 3 6 Max Rated Input Wattage Rating Watts 857 847 824 825 820 820 820 Max Rated VA Volt Amp 894 884 859 859 854 854 854 Efficiency at Max Rated Output Wattage 87 5 88 5 91 91 91 5 91 5 91 5 Power Factor 0...

Page 34: ...EC IEC power cord ships standard NOTE HP ProLiant DL servers no longer ship standard with NEMA power cords 163719 002 that allow connection to 110V US wall outlets in a home or office ProLiant DL servers are primarily connected to PDU s in data center racks so they now ship standard with only a PDU power cord 416151 B21 If a user wishes to power a ProLiant DL server using a 110V receptacle NEMA 15...

Page 35: ...tput per power supply Rated Steady State Power 500 Watts at 100 VAC 500 Watts at 200 VAC Maximum Peak Power 500 Watts at 100 VAC 500 Watts at 200 VAC Optional High Efficiency Power Supply Specifications Input Requirements per power supply Rated Line Voltage 90 110 VAC 108 132 VAC 180 264VAC Rated Input Current 7 4 A at 115 VAC 3 6 A at 230 VAC Rated Input Frequency 47 to 63 Hz Rated Input Power 84...

Page 36: ...ude change rate is 609 m min 2000 ft min Non operating 9144 m 30 000 ft Maximum allowable altitude change rate is 609 m min 2000 ft min Acoustic Noise Listed are the declared A Weighted sound power levels LWAd and declared average bystander position A Weighted sound pressure levels LpAm when the product is operating in a 23 C ambient environment Noise emissions were measured in accordance with ISO...

Page 37: ...ovides up to 4 2 GB s maximum bandwidth Server Interface x8 2 5G PCIe 2 0 provides 2GB s maximum bandwidth SAS Speed x8 6Gb s SAS provides 4 8GB s maximum bandwidth Cache Memory 40 bit 256MB ECC protected cache 72 bit 512MB BBWC module upgrades available transportable with battery backed upgrade Logical Drives Supported Up to 64 logical drives Host Memory Addressing 64 bit supporting greater than ...

Page 38: ...a responsible manner The EU WEEE directive 2002 95 EC requires manufacturers to provide treatment information for each product type for use by treatment facilities This information product disassembly instructions is posted on the Hewlett Packard web site at http www hp com go green These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who inte...

Reviews: