Installing the ProCurve Switch 8100fl
Installation Procedures
6. Tighten the captive screw on each ejector by hand and seat with a screw
driver to keep the module from being removed accidentally. Do not
overtighten the captive screws. (You can tighten the thumb screws with
a P2 Phillips screwdriver to eliminate the possibility of casual removal by
unauthorized personnel.)
2. Install management
modules on either side
of the two central slots.
3. Push in ejectors in to
secure and tighten
captive screws.
1. Pull out upper ejector
lever to hold it in
unlocked position.
Management
Module
Metal Plate
Module Guides
C a u t i o n
The management module must be fully seated and the ejectors fully
locked (vertical) before the captive screws will align properly. Also, fully
seating the card ensures proper contact of the card with the backplane
which is necessary for optimal performance.
7. Repeat steps 1 to 6 to install a secondary management module to provide
full (100%) redundancy in the event of a failure of the primary module.
Inst
all
ing t
he Pro
C
u
rve
Switch 8
100fl
2-21
Summary of Contents for ProCurve 8116fl
Page 1: ...Installation and Getting Started Guide ProCurve Series 8100fl Switches www procurve com ...
Page 2: ......
Page 3: ...ProCurve Series 8100fl Switches Installation and Getting Started Guide ...
Page 10: ... This page is intentionally unused ...
Page 26: ... This page is intentionally unused ...
Page 60: ... This page is intentionally unused ...
Page 72: ... This page is intentionally unused ...
Page 88: ... This page is intentionally unused ...
Page 122: ... This page is intentionally unused ...
Page 133: ......