![HP ProCurve 1600M Management And Configuration Manual Download Page 553](http://html.mh-extra.com/html/hp/procurve-1600m/procurve-1600m_management-and-configuration-manual_155305553.webp)
Monitoring and Analyzing Switch Operation
Traffic Mirroring
Syntax:
mirror endpoint ip <
src-ip
> <
src-udp-port
> <
dst-ip
> <
port-#
>
no mirror endpoint ip <
src-ip
> <
src-udp-port
> <
dst-ip
>
< src-udp-port > :
Must exactly match the
< src-udp-port >
setting you will configure in the source switch for the re
mote mirroring session the exit switch is being configured
to support. (The recommended range is 7933-65535.)
This setting associates the source mirroring session with
the desired
mirror endpoint
.by using the same, unique UDP
port number to identify a given mirroring session on a
source switch and the session’s corresponding destination
on a remote exit switch.
< dst-ip >:
Must exactly match the
< dst-ip >
setting configured
in the source switch for the remote mirroring session the
exit switch is being configured to support.
< port-# > :
Exit port for mirrored traffic from the specified
session. This is the port to which a traffic analyzer or IDS
should be connected.
Note:
On the remote exit switch, the mirrored traffic entry
port for a given session and the exit port for that session
must belong to the same VLAN.
3. Configure the Mirroring Session on the Source Switch
For local mirroring, only a session number and a destination port number are
needed. (You also have the option of associating a name with the session
number.) Refer to “Configuring Mirroring with a Destination on the Local
(Source) Switch” below.
If the mirroring destination is on a remote switch instead of the local (source)
switch, then the traffic source IP address, the mirroring destination IP address,
and a unique (randomly selected) UDP port number are required for the
mirroring session. (Refer to page B-44.)
Configuring Mirroring with a Destination on the Local (Source)
Switch.
For a given mirroring session on a source switch, use this command
to specify the exit port to use on the same switch. To create the mirroring
session itself, refer to the options under “1. Determine the Mirroring Session
Identity and Destination” on page B-41.
B-43
Summary of Contents for ProCurve 1600M
Page 1: ...Management and Configuration Guide 8200zl ProCurve Switches K 12 XX www procurve com ...
Page 2: ......
Page 3: ...ProCurve Series 8200zl Switches September 2007 K 12 xx Management and Configuration Guide ...
Page 68: ...Using the Menu Interface Where To Go From Here 3 16 ...
Page 110: ...Using the ProCurve Web Browser Interface Status Reporting Features 5 26 ...
Page 152: ...Switch Memory and Configuration Multiple Configuration Files 6 42 ...
Page 220: ...Time Protocols SNTP Messages in the Event Log 9 28 ...
Page 252: ...Port Status and Configuration Uni Directional Link Detection UDLD 10 32 ...
Page 282: ...Power Over Ethernet PoE Operation PoE Operating Notes 11 30 ...
Page 472: ...Redundancy Switch 8212zl Event Log Messages 15 48 ...
Page 584: ...Monitoring and Analyzing Switch Operation Locating a Device B 74 ...
Page 652: ...Troubleshooting Restoring a Flash Image C 68 ...
Page 660: ...MAC Address Management Viewing the MAC Addresses of Connected Devices D 8 ...
Page 666: ...Monitoring Resources When Insufficient Resources Are Available E 6 ...
Page 670: ...Daylight Savings Time on ProCurve Switches F 4 ...
Page 688: ...18 Index ...
Page 689: ......