File Transfers
Copying Diagnostic Data to a Remote Host, USB Device, PC or UNIX Workstation
Syntax:
copy crash-data <
source
> <
destination
> [<
ip-addr
> |<
filename
> |
unix | pc]
These commands copy the crash data content from a specified
source to a specified destination.
source:
Specifies the source of the data, which can be
tftp
,
xmodem
,
command
,
usb
, or any of the following switch files:
running configuration file
startup configuration file
crash-log (slots a -h, mm)
crash-data
event-log
command-output <
command
>
Note
: When using ‘command-output’, put the desired CLI
command in double quotes, for example, “show system”.
Note
: For 8200zl switches—When selecting
mm
as the source,
both the active and standby management modules’ crash data
is copied to a user-specified file. If no parameter is specified,
files from all modules (management and interface) are
concatenated.
destination:
Specifies the target to be copied to, which can be:
tftp
xmodem
usb
startup-configuration file
command-file
flash
pub-key-file
options:
The options are:
IP-Addr
- tftp server address, required for tftp transfers
filename
- filename to upload or download, required for
tftp and usb transfers
unix
pc
For example, to copy the switch’s crash data to a file in a PC:
At this point, press
[Enter]
and start the
Xmodem command
sequence in your
terminal emulator.
A-35
Summary of Contents for ProCurve 1600M
Page 1: ...Management and Configuration Guide 8200zl ProCurve Switches K 12 XX www procurve com ...
Page 2: ......
Page 3: ...ProCurve Series 8200zl Switches September 2007 K 12 xx Management and Configuration Guide ...
Page 68: ...Using the Menu Interface Where To Go From Here 3 16 ...
Page 110: ...Using the ProCurve Web Browser Interface Status Reporting Features 5 26 ...
Page 152: ...Switch Memory and Configuration Multiple Configuration Files 6 42 ...
Page 220: ...Time Protocols SNTP Messages in the Event Log 9 28 ...
Page 252: ...Port Status and Configuration Uni Directional Link Detection UDLD 10 32 ...
Page 282: ...Power Over Ethernet PoE Operation PoE Operating Notes 11 30 ...
Page 472: ...Redundancy Switch 8212zl Event Log Messages 15 48 ...
Page 584: ...Monitoring and Analyzing Switch Operation Locating a Device B 74 ...
Page 652: ...Troubleshooting Restoring a Flash Image C 68 ...
Page 660: ...MAC Address Management Viewing the MAC Addresses of Connected Devices D 8 ...
Page 666: ...Monitoring Resources When Insufficient Resources Are Available E 6 ...
Page 670: ...Daylight Savings Time on ProCurve Switches F 4 ...
Page 688: ...18 Index ...
Page 689: ......