![HP ProBook x360 435 G7 Product End-Of-Life Disassembly Instructions Download Page 27](http://html.mh-extra.com/html/hp/probook-x360-435-g7/probook-x360-435-g7_product-end-of-life-disassembly-instructions_2173989027.webp)
Operation instruction
Fixture list(fixture specification)
Qty
Fixture list(fixture specification)
Qty
Steps
:
Document No. : Primrose disassembly SOP
Station
:
Operation name : Ver. : 0.10 editing date : 2020/2/27
Issuing department
:
Prepared
:
Zhou Guiling
IE
Note: in case of any abnormality, please inform the foreman of assistant immediately
22(1/2)
1.Disassemble screw*1
。
(figure1)
❖
Screw material No : 6052B0156201 (M2.0x2.0)
❖
Torque
:
1.5 ± 0.2 Kgf
.
cm
❖
Do not slide the screw when disassembling
2. Take out fpr bracket from the fixing groov of upper
shell(figure2/3)
When taking out ,first lift the left end to the
left to exit the right insertion part, and
then take out the BKT.
remove Finger print
1
2
3
With Fingerprint SKU
Fingerprint vacuum suction assembly fixture
1
Cross electric screwdriver head
FPR Bracket
Location
post