Document No. : Primrose disassembly SOP

Station 

:

Operation name :                                                              Ver. :   0.10    editing date : 2020/2/27

Issuing department

Prepared

Zhou Guiling

IE

Note: in case of any abnormality, please inform the foreman of assistant immediately

20(1/1)

1. Slowly remove the cooling copper foil from the 

position as shown in the figure1

Take care not to damage 2

nd

camera and nearby 

FFC during  tearing FFC,etc.

2. Disassemble the 2

nd

camera screw*1

(figure2)

Screw material No : 6052B0156301 (M2.0x2.0)

Torque

1.5  ± 0.2 Kgf

cm

The screw shall not slip when locking

3. Remove 2nd Camera/B & Camera Module

(figure3)

4. Remove the Camera Module FPC from the 2

nd

camera/B CNTR

(figure4)

Open the CNTR piano cover before exiting the FPC

dismantling2nd Camera

With 2nd Camera SKU

2

1

3

4

Summary of Contents for ProBook x360 435 G7

Page 1: ...ed within the product which require selective treatment in the right column as applicable Item Description Notes Quantity of items included in product Printed Circuit Boards PCB or Printed Circuit Assemblies PCA With a surface greater than 10 sq cm Batteries excluding Li Ion batteries All types including standard alkaline coin or button style batteries Li Ion batteries Include all Li Ion batteries...

Page 2: ...ceramic fibers 0 Components parts and materials containing radioactive substances 0 2 0 Tools Required List the type and size of the tools that would typically be used to disassemble the product to a point where components and materials requiring selective treatment can be removed Tool Description Tool Size if applicable Electric screwdriver Cross Cross 1 Screwdriver 2 Screwdriver 3 3 0 Product Di...

Page 3: ...tructions for this template are available at EL MF877 01 3 2 Optional Graphic If the disassembly process is complex insert a graphic illustration below to identify the items contained in the product that require selective treatment with descriptions and arrows identifying locations ...

Page 4: ...0 10 21 0 10 6 0 10 14 0 10 22 0 10 7 0 10 15 0 10 8 0 10 16 0 10 Sta Ver ALL 0 1 2020 2 27 首份SOP制作 王興洪 A Current station version list B Version Modify list Date Content Design Written by 周贵玲 Date 2020 2 27 Page 1 of 25 Sub assembly name Primrose 拆机 SOP Document No Primrose 拆机 SOP Revision 0 10 MANUFACTURING PROCESS INSTRUCTIONS MECHANICAL ASSEMBLY MODEL Primrose ...

Page 5: ...tment Prepared Zhou Guiling IE Note in case of any abnormality please inform the foreman of assistant immediately 1 1 1 1 Disassemble the screws 5 on the lower of the base according to the sequence shown in the figure Disassemble screw A directly up and down Torque 2 5 0 2 Kgf cm Do not slide the screw or withdraw the lower cover during disassembly Disassemble the base screw Cross electric screwdr...

Page 6: ...ent Prepared Zhou Guiling IE Note in case of any abnormality please inform the foreman of assistant immediately 2 1 1 图一 Disassembly of base cover2 Cross electric screwdriver head 1 1 1 Disassemble the screws 2 on the lower of the base according to the sequence shown in the figure Disassemble screw A directly up and down Torque 2 5 0 2 Kgf cm Do not slide the screw or withdraw the lower cover duri...

Page 7: ...partment Prepared Zhou Guiling IE Note in case of any abnormality please inform the foreman of assistant immediately 3 1 1 1 Use the disassembly bar to pry off the base cover from the hinge cap and hook according to the sequence shown in the figure and then place it in the material box 2 Order of disassembly 1 2 3 The base cover magnet can not be attached other screws Remove the base cover disasse...

Page 8: ...e foreman of assistant immediately 4 1 1 1 According to the sequence shown in the figure remove the fixing screws 4 figure 1 Torque 1 5 0 2 Kgf cm Do not slide the screw when disassembling 2 Remover battery from the machine figure2 Lift the CR end of battery up to 45 and take it out There are stops at the lower left and right corners which can not damage the hook and battery Take out the battery a...

Page 9: ... 10 editing date 2020 2 27 Issuing department Prepared Zhou Guiling IE Note in case of any abnormality please inform the foreman of assistant immediately 5 1 1 1 1 Remover the DDR shield Bracket from MB and place it in the material box Make M B Clips19 figure2 When taking DDR shield Bracket do not damage the upper M B components Disassembly DDR Shield Bracket 2 Clips共19處 ...

Page 10: ...n Operation name Ver 0 10 editing date 2020 2 27 Issuing department Prepared Zhou Guiling IE Note in case of any abnormality please inform the foreman of assistant immediately 6 1 1 1 2 Remover SSD shield Bracket from M B Make M B Clips 13 figure2 When taking DDR shield Bracket do not damage the upper M B components Disassembly SSD Shield Bracket 2 ...

Page 11: ... Note in case of any abnormality please inform the foreman of assistant immediately 7 1 2 1 1 Open the buckle of the main DDR with both hands at the same time and the DDR will pop up to the tilt automatically figure2 2 Take it out in the direction of DDR figure3 Do not operate with one hand figure3 Do not damage the M B components When taking DDR do not touch the PIN plug in must not be skewed Dis...

Page 12: ... of assistant immediately DDR disassembly specification 1 Only one ram can be taken and put at a time when taking and putting fingers can only hold both sides of ram figure1 do not press one side of ram and lift it up from the other side figure2 Two or more RAM can not be taken and placed at the same time by each hand figure3 do not take the place as figure4 do not press the golden finger as figur...

Page 13: ...Guiling IE Note in case of any abnormality please inform the foreman of assistant immediately 8 1 1 1 1 Remove K b menbrance from M b CNTR figure1 Open the piano cover of CNTR and exit the line Do not pull K B Membrane do not press the broken line of KB membrane figure2 2 Disassemble K b backlight FPC from M b CNTR figure1 Open the piano cover of CNTR and exit the line Do not pull K B Backlight FP...

Page 14: ...any abnormality please inform the foreman of assistant immediately 9 1 1 1 1 Remove click pad FFC from M b CNTR figure1 Open the piano cover of CNTR and exit the line Do not pull FFC 2 Remove 2nd camera FFC from M b CNTR figure1 Open the piano cover of CNTR and exit the line Do not pull FFC 3 Remove Fingerprint FFC from M b CNTR figure2 Open the piano cover of CNTR and exit the line Do not pull FF...

Page 15: ...rom the module terminal block figure1 When taking out the antenna do not damage the terminal on the antenna module Exit the antenna from the hook 2 Take EDP cable CNTR figure1 Hold the cable terminal and lift it up gently Do not use too much force to prevent personnel from damaging the cable Withdraw the cable from the card hook 3 remove the webcame cable CNTR from the M b figure2 Hold the cable t...

Page 16: ...reman of assistant immediately 11 1 1 1 1 Remove DC in cable from M b CNTR figure1 Push back DC in cable CNTR with both thumbs until exiting M B CNTR 2 Screw the holder hinge in the order shown in the figure figure2 Torque 1 5 0 2 Kgf cm Do not slide the screw when disassembling 1 Take out the holder and place it in the material box Take care not to damage the components 2 Cross electric screwdriv...

Page 17: ... 1 1 1 1 Open the hinge to about 100 to 110 and place it on the load support fixture figure1 2 Dismantle the screw 7 at the upper end of hinge main figure2 figure3 Do not scratch hinge cap during disassembly Do not pull Hinge up cable Do not collide with MB parts Do not slide the screw Screw material NO 6052A0010401 M2 5x6 0 Torguq 3 0 0 2 Kgf cm 3 Take out the upper part and main upper part 2 Cro...

Page 18: ...eman of assistant immediately 13 1 1 disassemble WLAN WWAN SSD 1 1 Remove the screw 1 figure1 Screw material NO 6052B0156201 M2 0x2 0 Torque 1 5 0 2 Kgf cm Screw do not slide back when disassembling 2 Disassemble fix SSD module screw 1 figure2 Screw material NO 6052B0156201 M2 0x2 0 Torque 1 5 0 2 Kgf cm Screw do not slide back when disassembling 3 take out WLAN Module and SSD Module It s hard to ...

Page 19: ...ty please inform the foreman of assistant immediately 14 1 1 disassembly Thermal Module 1 1 Disassemble fixing screws 6 figure1 Torque 1 5 0 2 Kgf cm Do not slide the screw when disassembling It must be disassembled in the order1 2 3 4 5 6 2 Remover the Thermal Module Note that the right cooling fin is inserted obliquely so first lift the left side and then exit the fin figure2 2 Cross electric sc...

Page 20: ...Prepared Zhou Guiling IE Note in case of any abnormality please inform the foreman of assistant immediately 15 1 1 Dismantling FAN Speaker Cable Cross electric screwdriver head 1 1 1 1 Exit fan cable CNTR and speaker cable figure1 2 When exiting cable CNTR do not tilt or pull it out violently 2 Remove and fix fan module screw 1 figure2 扭力 1 5 0 2 Kgf cm Do not slide the screw when disassembling 3 ...

Page 21: ...E Note in case of any abnormality please inform the foreman of assistant immediately 16 1 1 Dismantling USB Bracket RTC battery 1 1 Disassemble the USB bracket bolts screws 2 in the sequence shown in the figure1 Torque 1 5 0 2 Kgf cm Do not slide the screw when disassembling 2 Remove USB Bracket 3 Remove the RTC battery cable from the plastic part and exit from the hook figure3 2 3 USB Bracket 雙面背...

Page 22: ...0 2 27 Issuing department Prepared Zhou Guiling IE Note in case of any abnormality please inform the foreman of assistant immediately 17 1 1 Disassemble M B Screw 1 1 Disassemble the M B screw 5 according to the sequence shown in the figure1 Screws material NO 6052A0053001 M2 0x2 5 Torque 1 5 0 2 Kgf cm Do not slide the screw when disassembling Cross electric screwdriver head 1 1 1 2 3 4 5 ...

Page 23: ...ing department Prepared Zhou Guiling IE Note in case of any abnormality please inform the foreman of assistant immediately 18 1 1 Remove MB from upper cover 2 2 3 1 Location post Audio Jack 1 Remove M B figure1 Slowly lift the right end of M B then exit the left end of audio jack Take out M B again M B components shall not be damaged during removal 2 Take out DC in cable figure2 figure3 Speaker ca...

Page 24: ...ight corner of Support Bracket figure1 2 Torque 1 5 0 2 Kgf cm Screw should not slip at the time of disassembly 2 Remove 2nd Camera Bracket figure3 when the positioning column is removed it must not to damage the plastic parts Disassembly 2nd Camera 1 2 With 2nd Camera SKU Cross electric screwdriver head 1 1 3 Without 2nd Camera SKU Without 2nd Camera SKU 1 Disassemble the screw 1 at the lower rig...

Page 25: ...ately 20 1 1 1 Slowly remove the cooling copper foil from the position as shown in the figure1 Take care not to damage 2nd camera and nearby FFC during tearing FFC etc 2 Disassemble the 2nd camera screw 1 figure2 Screw material No 6052B0156301 M2 0x2 0 Torque 1 5 0 2 Kgf cm The screw shall not slip when locking 3 Remove 2nd Camera B Camera Module figure3 4 Remove the Camera Module FPC from the 2nd...

Page 26: ...mality please inform the foreman of assistant immediately 21 1 1 1 Disassembly FPR dummy screw 1 figure1 Screw material No 6052B0156201 M2 0x2 0 Torque 1 5 0 2 Kgf cm Do not slide the screw when diassembling 2 Remove FPR Dummy figure2 Lift over the left and exit the right end and insert the part then take it out Remove Finger print Dummy 1 2 3 Without Fingerprint SKU Fingerprint vacuum suction ass...

Page 27: ...of assistant immediately 22 1 2 1 Disassemble screw 1 figure1 Screw material No 6052B0156201 M2 0x2 0 Torque 1 5 0 2 Kgf cm Do not slide the screw when disassembling 2 Take out fpr bracket from the fixing groov of upper shell figure2 3 When taking out first lift the left end to the left to exit the right insertion part and then take out the BKT remove Finger print 1 2 3 With Fingerprint SKU Finger...

Page 28: ... of any abnormality please inform the foreman of assistant immediately 22 2 2 1 Remove the finger print module from the upper shall figure1 Hold the appearance of finger print module on the top page with your fingers and remove it 2 disassemble fpr FFC on finger print module figure2 Open the CNTR piano cover before exiting FFC Removal Finger print Fingerprint vacuum suction assembly fixture 1 Cros...

Reviews: