Cable Specifications
The following table lists the types of cables commonly required for the installation of HP P10000
3PAR Storage Systems.
Table 7 Required Cables
Connector Type
Cable Type
RJ-45
Ethernet (Category 5) 3 cables minimum with 2 static IPs
LC-LC
Multimode Fibre Channel Requires 50 micron OM3 cables
for 8 or 10Gb/sec speeds.
The following table shows the typical Fibre Channel cable lengths required for a given type of
connection:
Table 8 Fibre Channel Cable Usage Guidelines
Used for...
Cable Length
drive chassis to controller node connections in the same
cabinet.
6 m
cabling between cabinets. Always round up to the nearest
size.
4 m
10 m
25 m
50 m
100 m
The following table shows the maximum supported Fibre Channel cable length based on the cable
size and port speed.
Table 9 Cable Limitations for Fibre Channel Host Connectivity
Cable Length Limit
Speed
Cable Size
300 meters
4, 8 or 10 Gb/s
50 micron
150 meters
4, 8 or 10 Gb/s
50 micron
NOTE:
Refer to
“Network, Cabling and Connectivity” (page 41)
for more details on cable
requirements and configurations.
Cable Specifications
13
Summary of Contents for P10000
Page 30: ...Figure 12 Power Supplies Within the Power Domains 30 Power Requirements ...
Page 59: ...French battery notice German battery notice Battery replacement notices 59 ...
Page 60: ...Italian battery notice Japanese battery notice 60 Regulatory compliance notices ...
Page 61: ...Spanish battery notice Battery replacement notices 61 ...