12
HP Switch zl Modules
FM1 ProCurve J9093A,Fabric Module E8200zl Enabled
FM2 ProCurve J9093A,Fabric Module E8200zl Enabled
Example when standby management the module has rebooted.
ProCurve Switch E8212zl# show redundancy
Settings
--------
Mgmt Redundancy : Enabled
Statistics
----------
Failovers : 3
Last Failover : Tue May 12 17:30:07 2009
Slot Module Description Status SW Version Boot Image
---- ---------------------------------------- --------
MM1 ProCurve J9092A Management Module
E8200zl Standby
K.13.60
Secondary
MM2 ProCurve J9092A Management Module E8200zl Active K.13.60 Secondary
FM1 ProCurve J9093A,Fabric Module E8200zl Enabled
FM2 ProCurve J9093A,Fabric Module E8200zl Enabled
4.
Perform Switchover
E8200zl#
redundancy switchover
This causes a switchover to the management module that received the
new software version, which becomes the active management module.
This method incurs the least amount of network downtime for booting. If
downtime is not an issue, use the
boot system
command. Both management
modules will then be running the new software version.
5.
Both management modules are now updated to new software. If two step
update is required repeat steps 1 through 4 again installing next step
software.
Note:
When a bootROM is updated with software after the boot standby command
is entered the switch will reboot twice, first to update the BootROM to new
version, and then to load the updated system software. Following file copy to
the switch flash and initiation of the boot standby command, no additional
user intervention is needed. Do not interrupt power to the switch during this
important update. See the release notes for additional information.
Summary of Contents for J8697A
Page 1: ...HP Switch zl Modules Installation Guide Power over Ethernet ...
Page 2: ......
Page 3: ...HP Switch zl Modules Installation Guide ...
Page 6: ......
Page 55: ......