Chapter 2
Installing the Server
Cabling and Power Up
81
Installing The Line Cord Anchor (for rack mounted servers)
The line cord anchor is attached to the rear of the server when rack mounted. It provides a method to secure
the line cords to the server preventing accidental removal of the cords from the server.
Two Cell Server Installation (rp7410, rp7420, rp7440, rx7620, rx7640)
There are 3 studs with thumb nuts located at the rear of the server chassis. The line cord anchor installs on
these studs.
To install the line cord anchor:
1. Remove and retain the thumb nuts from the studs.
2. Install the line cord anchor over the studs. Refer to Figure 2-27, “Two Cell Line Cord Anchor (rp7410,
rp7420, rp7440, rx7620, rx7640),”
3. Tighten the thumb nuts onto the studs.
4. Weave the power cables through the line cord anchor. Leave enough slack to allow the plugs to be
disconnected from the receptacles without removing the cords from the line cord anchor.
5. Use the supplied straps to attach the cords to the anchor. Refer to Figure 2-28, “Line Cord Anchor Attach
Straps,”
Figure 2-27
Two Cell Line Cord Anchor (rp7410, rp7420, rp7440, rx7620, rx7640)
Figure 2-28
Line Cord Anchor Attach Straps
Attach Straps