Troubleshooting 74
3.
Be sure no ventilation problems exist. If you have been operating the server for an extended period of
time with the access panel removed, airflow may have been impeded, causing thermal damage to
components. Refer to the server documentation for further requirements.
4.
Be sure no POST error messages are displayed while booting the server that indicate temperature
violation or fan failure information. Refer to the server documentation for the temperature requirements
for the server.
5.
Replace any required non-functioning fans and restart the server. Refer to the server documentation for
specifications on fan requirements.
6.
Be sure all fan slots have fans or blanks installed. Refer to the server documentation for requirements.
7.
Verify the fan airflow path is not blocked by cables or other material.
Hard drive problems
System completes POST but hard drive fails
Action
:
1.
Be sure no loose connections (on page
53
) exist.
2.
Be sure no device conflict exists.
3.
Be sure the hard drive is properly cabled and terminated if necessary.
4.
Be sure the SCSI cable is working by replacing it with a known functional cable.
5.
Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
51
) and replace failed components as
indicated.
Hard drive is not recognized by the server
Action
:
1.
Check the LEDs on the hard drive to be sure they indicate normal function. Refer to the server
documentation or the HP website for information on hard drive LEDs.
2.
Be sure no loose connections (on page
53
) exist.
3.
Remove the hard drive and be sure the configuration jumpers are set properly.
4.
If using an array controller, be sure the hard drive is configured in an array. Run the array configuration
utility.
5.
Be sure the drive is properly configured. Refer to the drive documentation to determine the proper
configuration.
6.
If it is a non-hot-plug drive, be sure a conflict does not exist with another hard drive. Check for SCSI ID
conflicts.
7.
Be sure the correct drive controller drivers are installed.
Data is inaccessible
Action
:
1.
Be sure the files are not corrupt. Run the repair utility for the operating system.
2.
Be sure no viruses exist on the server. Run a current version of a virus scan utility.
Summary of Contents for DL120 - ProLiant - G5
Page 46: ...Cabling 46 BBWC battery cabling to an optional controller Power supply 500 W cabling ...
Page 47: ...Cabling 47 SATA cabling SATA cabling to the SGPIO connector and the 12C cable connector ...
Page 49: ...Cabling 49 Fan cabling ...
Page 105: ...Technical support 105 ...
Page 106: ...Technical support 106 ...