
cc2300 Carrier Grade Server Product Guide
71
Replacement Disks
The SCSI address jumpers need to be removed from the failed disk and installed on the replacement
disk. Set the SCSI address on the replacement disk to match the failed disk’s SCSI address.
Installing a Second Disk Drive in the Server Chassis
Check the SCSI address setting on the disk drive that is already installed. The SCSI address will be
5 or 6. Set the SCSI address on the second disk so it doesn’t match the SCSI address of the
currently installed disk drive. Failure to set the SCSI address properly could result in a SCSI
address conflict.
Disk Types
Different hard drives are used in the server. Please refer to the following information to determine
the disk type being replaced or installed.
Part Number A6942-69001/A6943-69001
Product Number A6942A/A6943A
Jumper Settings
Summary of Contents for cc2300
Page 1: ...Hewlett Packard cc2300 Carrier Grade Server Product Guide Document Release Date March 2003 ...
Page 12: ......
Page 38: ......
Page 40: ......
Page 60: ......
Page 88: ......
Page 90: ...90 cc2300 Carrier Grade Server Product Guide Figure 26 Front Panel Board Removal ...
Page 106: ......
Page 118: ......
Page 130: ...130 cc2300 Carrier Grade Server Product Guide ...