Smart Array 91
4-4-2
HP_DeviceIndication: Physical Drive Status
Changed to ERROR
Table 4-87
HP_DeviceIndication: Physical Drive Status Changed to ERROR
Property name
Property implementation
VariableValues[]
FailureDescription short description of the failure
Drive interface HPSA_DiskDrive.DriveInterface
LastFailureDescription – last failure reason string from
the drive. HPSA_DiskDrive.OperationalStatus[1]
HP_DeviceIndication
DeviceModel
Physical Disk Model string
DeviceControllerLogicalLocation
Controller Location
For example, SmartArray 642 in Slot 2, Smart Array
P400 Embedded Controller=7” for embedded
controller where 7 is the internal identifier for the
embedded controller
4-4-3
HP_DeviceIndication: Physical Drive Status
Changed to REBUILDING
Table 4-88
HP_DeviceIndication: Physical Drive Status Changed to REBUILDING
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
2 (Informational)
IndicationTime
Time of indication
CIM_AlertIndication
Description
Physical drive status has changed to Rebuilding. Data
is now being rebuilt onto this drive from the array
system.
AlertingMangedElement
WBEM Path of SMX_SADiskDrive class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
203
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName
HP Smart Array