System Fan 199
Table 8-4
Class: SMX_FanRedundancySet
Property name
Property implementation
CIM_SystemSpecificCollection
InstanceID
Unique identifier for this cooling redundancy instance
CIM_RedundancySet
MaxNumberSupported
Represents the maximum number of fans supported for
this redundancy set
MinNumberNeeded
Represents the minimum number of fans needed to
function
TypeOfSet
3 (Load Balanced)
LoadBalanceAlgorithm
0 (Unknown)
RedundancyStatus
0 (Unknown)—if the redundancy status is unknown
2 (Fully Redundant)—if the all fans in the set are
operating properly and enough to achieve redundancy
3 (Degraded Redundancy)—if there are at least
enough fans for the redundancy set to provide cooling,
but fans have failed
4 (Redundancy Lost)—if there are not enough fans
required to achieve redundancy, but enough for the
redundancy set to provide cooling
5 (Overall Failure)—if there are not enough fans
operating properly for the redundancy set to provide
cooling.
8-3-4
SMX_MemberOfFanRedundancy
SMX_MemberOfFanRedundancy is used to represent an association between HP_Fan and
HP_FanRedundancySet.
Table 8-5
Class: SMX_MemberOfFanRedundancy
Property name
Property implementation
Collection
References HP_FanRedundancy
Member
References HP_Fan
8-3-5
SMX_HostedFanRedundancySet
SMX_HostedFanRedundancySet is used to represent an association between HP_FanRedundancySet
and the computer system that contains this redundancy set.
Table 8-6
Class: SMX_HostedCoolingRedundancySet
Property name
Property implementation