Smart Array 111
4-4-10
HP_DeviceIndication: Controller Redundancy state
has been set to Active
Table 4-95
HP_DeviceIndication: Controller Redundancy state has been set to Active
Property name
Property implementation
VariableTypes[]
String (1)
uint32 (5)
VariableValues[]
FailureDescription short description of the failure
CacheSizeTotal HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
DeviceModel
Array Controller Model string
4-4-11
HP_DeviceIndication: Controller Redundancy has
been lost
Table 4-96
HP_DeviceIndication: Controller Redundancy has been lost
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Smart Array controller has detected that redundancy
has been lost due to failure or loss of communication
with partner controller.
AlertingMangedElement
WBEM Path to SMX_SAArrayController class.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
4
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName
HP Smart Array
RecommendedActions
Check status of the partner array controller.
SystemName
Name of the computer system generating the indication