Smart Array 63
Table 4-20
Class: SMX_SAStorageSetting (CIM_StorageSetting)
Property name
Property implementation
CIM_SettingData
InstanceID
Opaque key
CIM_StorageSetting
ChangeableType
0 (Not Changeable)
DataRedundancyGoal
1 (RAID 0, RAID 5, RAID 6, RAID 50, RAID 60)
2 (RAID 1+0)
DataRedundancyMax
1 (RAID 0, RAID 5, RAID 6, RAID 50, RAID 60)
2 (RAID 1+0)
DataRedundancyMin
1 (RAID 0, RAID 5, RAID 6, RAID 50, RAID 60)
2 (RAID 1+0)
DeltaReservationGoal
0
DeltaReservationMax
0
DeltaReservationMin
0
NoSinglePointOfFailure
FALSE – RAID 0
TRUE – RAID 1+0, RAID 5, RAID 6
PackageRedundancyGoal
0 (RAID 0)
1 (RAID 1+0, RAID 5)
2 (RAID 6, RAID 50, RAID 60)
PackageRedundancyMax
0 (RAID 0)
1 (RAID 1+0, RAID 5)
2 (RAID 6, RAID 50, RAID 60)
PackageRedundancyMin
0 (RAID 0)
1 (RAID 1+0, RAID 5)
2 (RAID 6, RAID 50, RAID 60)
HPSA_StorageSetting
4-3-20
SMX_SADriveCage
SMX_SADriveCage implements the HPSA_DriveCage class and represents the drive cage assembly
and backplane within a storage enclosure. Multiple instances might occur within a duplexed
enclosure.
Table 4-21
Class: SMX_SADriveCage (CIM_PhysicalPackage)
Property name
Property implementation
CIM_ManagedElement