Smart Array 88
Table 4-86
HP_DeviceIndication: Physical Drive Status Changed to OK
Property name
Property implementation
SystemVirtualSerialNumber
Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion
Physical Disk F/W version string
HWLogicalLocation
Physical Disk Location string
For example, Port:1E Box: 1 Bay 5
HWPhysicalLocation
Physical Location of the Failed Drive (Bay Number)
HWSerialNumber
Physical Disk Serial Number
HP_DeviceIndication
DeviceModel
Physical Disk Model string
DeviceControllerLogicalLocation
Controller Location
For example, SmartArray 642 in Slot 2
VariableNames
Failure Description
DriveInterface
LastFailureDescription
VariableTypes[]
String (1)
uint16 (4)
VariableValues[]
FailureDescription short description of the failure
Drive interface HPSA_DiskDrive.DriveInterface
LastFailureDescription – last failure reason string from
the drive. HPSA_DiskDrive.OperationalStatus[1]
4-4-2
HP_DeviceIndication: Physical Drive Status
Changed to ERROR
Table 4-87
HP_DeviceIndication: Physical Drive Status Changed to ERROR
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication