222
Data Protector Express® User’s Guide and Technical Reference
Grace logons
Controls how many times a user can log on to Data Protector Express after their password has expired.
For example, if the
Allow grace logons
box is checked and the
Remaining grace logons
is set to
2
, the
user will be allowed to log on two times after their old password has expired. On the third logon attempt,
the user must change their password.
NOTE:
Grace logons do not function when passwords are not required, that is, when the
Require
password
check box is cleared.
Grace logons allowed:
If checked, a user can log on after their old password has expired.
Limit grace logons:
Shows the maximum number of grace logons allowed. For example, if it is set to
2
,
the user can log on with an expired password two times.
Remaining grace logons:
Shows the number of remaining grace logons. Data Protector Express
automatically adjusts this number each time the user logs on with expired password. You can also set this
manually.
Password
Controls whether a user must have a password to log on.
Require password:
When checked, Data Protector Express requires the user to have a password.
NOTE:
If you clear the
Require
password
box and the user has a password, Data Protector Express will
continue to require that user to input their password.
Minimum password length:
Specifies the minimum length of the password.
Require unique passwords:
If checked, Data Protector Express only accepts the new password if the user
has not used it before.
Force periodic password changes:
If checked, either the user or the Data Protector Express administrator
must change the password per the
Days between forced changes
and
Date password expires
settings.
Days between forced changes:
Specifies the interval between forced password changes.
Date password expires:
Calculated date of next password expiration, based on
Days between forced
changes
setting.
Allow user to change password:
If checked, the user can change their password on their own.
TIP:
The Data Protector Express administrator can change a user’s password without knowing the user’s
current password. Data Protector Express does not even ask you to enter the old password. This is useful
when the user has forgotten his or her password.
Connection
Controls the allowable machines and simultaneous logons for a user.
Concurrent connections:
Controls how many different logons a user may have simultaneously from
different machines. For example, if the
Number of concurrent connections
is set to
5
, this user can log
on to Data Protector Express from up to five separate machines at the same time.
User can log on from these machines:
Lists the machines from which a user can log on to Data Protector
Express. The user cannot log on to Data Protector Express from any machine unless it is listed. To add
machines, click
Add…
and select the appropriate machine from the
Browse
dialog box. To remove
machines, select the machine and click
Delete
.
Summary of Contents for BB118BV - StorageWorks Data Protector Express Package
Page 1: ...U s e r s Gu i d ea n dT e c h n i c a l R e f e r e n c e ...
Page 339: ......
Page 345: ......