Specifications 51
Rated input current
4.5 A at 200 V AC
3.2 A at 277 V AC
2.3 A at 380 VDC
Maximum rated input power
900 W at 200 VAC
887 W at 277 VAC
874 W at 380 VDC
BTUs per hour
3071 at 200 VAC
3026 at 277 VAC
2982 at 380 VDC
Power supply output
Rated steady-state power
800 W at 200 VAC to 277 VAC
input
800 W at 380 VDC input
Maximum peak power
800 W at 200 VAC to 277 VAC
input
800 W at 380 VDC input
HPE 1400W Flex Slot Platinum Plus Hot-plug Power Supply
Specification
Value
Input requirements
Rated input voltage
200 to 240 VAC
240 VDC for China only
Rated input frequency
50 Hz to 60 Hz
Not applicable to 240 VDC
Rated input current
8.0 A at 200 VAC
6.7 A at 240 VAC
6.7 A at 240 VDC for China only
Maximum rated input power
1600 W at 200 VAC
1600 W at 240 VAC
1600 W at 240 VDC for China
only
BTUs per hour
5459 at 200 VAC
5459 at 240 VAC
5459 at 240 VDC for China only
Power supply output
Rated steady-state power
1400 W at 200 VAC to 240 VAC
input
1400 W at 240 VDC input for
China only
Maximum peak power
1400 W at 200 VAC to 240 VAC
input
1400 W at 240 VDC input for
China only
Hot-plug power supply calculations
For hot-plug power supply specifications and calculators to determine electrical and heat loading for the
server, see the Hewlett Packard Enterprise Power Advisor website
Summary of Contents for apollo 4510 gen9
Page 20: ...Identifying components and LEDs 20 Optional 8 LFF drive cage bay numbering ...
Page 32: ...Installing the chassis 32 Installing a management module Install the component as indicated ...
Page 60: ...Support and other resources 60 ...
Page 61: ...Support and other resources 61 ...
Page 64: ...Acronyms and abbreviations 64 UPS uninterruptible power system USB universal serial bus ...
Page 68: ...Index 68 W warranty 46 warranty information 46 website Hewlett Packard Enterprise 54 ...