Installing the chassis 25
b.
Remove the system fans from all 5 fan bays.
Install the chassis into the rack
WARNING:
Always have at least two people to lift the chassis into the rack. If the chassis is
being loaded into the rack above chest level, an additional person must assist with aligning the
chassis with the rails while the other people support the weight of the chassis.
WARNING:
The chassis is very heavy. To reduce the risk of personal injury or damage to the
equipment:
•
Observe local occupational health and safety requirements and guidelines for manual
material handling.
•
Remove all installed components from the chassis before installing or moving the chassis.
•
Use caution and get help to lift and stabilize the chassis during installation or removal,
especially when the chassis is not fastened to the rack.
WARNING:
To avoid risk of personal injury or damage to the equipment, do not stack
anything on top of rail-mounted equipment or use it as a work surface when extended from the
rack.
CAUTION:
Always plan the rack installation so that the heaviest item is on the bottom of the
rack. Install the heaviest item first, and continue to populate the rack from the bottom to the top.
CAUTION:
Hewlett Packard Enterprise has not tested or validated the Apollo 4510 Gen9
Chassis with any third-party racks. Before installing the Apollo 4510 Gen9 Chassis in a
third-party rack, be sure to properly scope the limitations of the rack. Before proceeding with
the installation, consider the following:
•
You must fully understand the static and dynamic load carrying capacity of the rack and be
sure that it can accommodate the weight of the Apollo 4510 Gen9 Chassis.
•
Be sure sufficient clearance exists for cabling, installation and removal of the chassis, and
actuation of the rack doors.
The chassis requires rails for installation in a rack. To install the rack rails, see the
Quick Deploy Rail
System Installation Instructions
that ship with the rack hardware kit.
You can install up to nine chassis in a 36U, 1200mm deep rack. If you are installing more than one
chassis, install the first chassis in the bottom of the rack, and then install additional chassis by moving up
Summary of Contents for apollo 4510 gen9
Page 20: ...Identifying components and LEDs 20 Optional 8 LFF drive cage bay numbering ...
Page 32: ...Installing the chassis 32 Installing a management module Install the component as indicated ...
Page 60: ...Support and other resources 60 ...
Page 61: ...Support and other resources 61 ...
Page 64: ...Acronyms and abbreviations 64 UPS uninterruptible power system USB universal serial bus ...
Page 68: ...Index 68 W warranty 46 warranty information 46 website Hewlett Packard Enterprise 54 ...