8.
Install any expansion board options
.
9.
Connect all necessary internal cabling to the expansion board. For more information on these cabling
requirements, see the documentation that ships with the option.
10.
Install the single-slot 1U node right PCI riser cage assembly and then secure it with four T-10 screws.
11.
Do one of the following:
•
Install the 1U left rear I/O blank
•
Install the single-slot left PCI riser cage assembly
.
CAUTION:
To prevent improper cooling and thermal damage, do not operate the node unless all PCI riser
cages or rear I/O blanks are installed, and do not operate the node unless all PCI slots have
either an expansion slot cover or an expansion board installed.
IMPORTANT:
If the PCIe riser cage assembly is not seated properly, then the server does not power up.
12. Install the node into the chassis
.
96
Hardware options installation