b. Install the FlexibleLOM 2U node riser cage assembly and secure it with five T-10 screws
CAUTION:
To prevent improper cooling and thermal damage, do not operate the node unless all PCI riser
cages or rear I/O blanks are installed, and do not operate the node unless all PCI slots have
either an expansion slot cover or an expansion board installed.
IMPORTANT:
If the PCIe riser cage assembly is not seated properly, then the server does not power up.
10. Install the node into the chassis
.
11.
Connect all peripheral cables to the node.
FlexibleLOM 1U node riser cage assembly option
Procedure
1.
2.
Disconnect all peripheral cables from the node.
3.
Remove the node from the chassis
4.
Place the node on a flat, level surface.
5.
remove the single-slot left PCI riser cage assembly
.
6.
7.
Remove the PCI blank.
98
FlexibleLOM 1U node riser cage assembly option