11
Description of LEDs on the Remote 2C
The Remote 2C has the following LEDs:
LED
State
Meaning
Power
(green)
ON
OFF
The Remote 2C is receiving power.
The Remote 2C is not receiving power.
Global Fault
(orange)
ON
One or both slot modules experienced a hardware problem.
RPS
(green)
OFF
ON
Flashing
The Remote 2C is not receiving power from the HP J2962A Redundant Power Supply (RPS).
The Remote 2C is receiving power from the connected RPS.
An error has occurred on the RPS connected to the Remote 2C. See the documentation
provided with the RPS for troubleshooting.
10Base-T
(green)
ON
The corresponding module is connected to a 10Base-T or Ethernet
network.
100VG
(green)
ON
OFF
The corresponding module is connected to a 100VG network.
The port is not connected to any network or no slot module is present.
In Use
(green)
ON
OFF
The module is inserted in the slot correctly.
A module is not inserted in the slot or is inserted incorrectly.
Act(ivity)
(green)
Flickering
Shows the amount of activity for the network connected to a port.
Link OK
(green)
On
Off
Flashing
The LAN connected to the RJ-45 connector is providing link beat (Ethernet) or training was
successful (100VG).
Link beat is not detected.
The port is partitioned because of excessive collisions.
Slot Specific
LEDs (4)
See the manual for that module for LED behavior.
Slot Fault
(orange)
On
Off
This module has experienced a failure. See Troubleshooting on page 13.
The normal state. Indicates that there are no fault conditions on the module. Refer to the
four slot specific LEDs for more troubleshooting information.
abner.bk : 1_instal.fm5 Page 11 Monday, June 23, 1997 2:40 PM