13
Troubleshooting the Remote 2C
Use the following table to determine the problem with your Remote 2C. Also consult the LED table
on page 11. If you are still having problems with the Remote 2C, see the Customer Support page at
the beginning of this manual for information on how to contact HP.
Problem
Solution
All LEDs are lit on the Remote 2C
and remain lit.
Verify that each module is fully inserted, extractor handles down, screws tightened.
The 10Base-T or 100VG LED for a
twisted-pair port is not lit when a
cable is connected.
Verify that the cable is secure and is 4-pair, Category 3 or better.
Try a different cable.
Verify that the connected device is powered on.
Try a different port.
Verify that the cable length did not exceed 100 meters.
Verify that the port is
enabled and not disabled.
Verify that the module is fully inserted and the appropriate “In Use” LED is on.
The Fault LED is on for a module. Remove and insert the module into a different slot. If the symptoms are the same,
contact your HP-authorized reseller or dealer to replace the module.
abner.bk : 1_instal.fm5 Page 13 Monday, June 23, 1997 2:40 PM