Page 1: ...Installation and Reference Guide HP J3257A HP AdvanceStack Remote 2C abner bk 0_fcvr fm5 Page 1 Monday June 23 1997 2 40 PM ...

Page 2: ...abner bk 0_fcvr fm5 Page 2 Monday June 23 1997 2 40 PM ...

Page 3: ...HP AdvanceStack Remote 2C Installation and Reference Guide abner bk 0_front fm5 Page vii Monday June 23 1997 2 40 PM ...

Page 4: ...ut notice HEWLETT PACKARD COMPANY MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THISMATERIAL INCLUDING BUTNOTLIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Hewlett Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material Hewlett Packard assumes n...

Page 5: ... To the Office LAN 7 Connecting an HP Remote 2C and HP Internet Router Module To a 100VG Network 9 Connecting Power using an RPS or AC Power 9 Description of LEDs on the Remote 2C 11 Where to Go From Here 12 Removing A Module from the Remote 2C 12 Troubleshooting the Remote 2C 13 Specifications 14 Safety and Regulatory Statements Mounting Precautions 17 Power Precautions 18 Safety Information 19 R...

Page 6: ...iv ...

Page 7: ...ax retrieval service that is available 24 hours a day seven days a week HP FIRST provides information on the following topics Product information Troubleshooting instructions Technical reviews and articles Configuration information To access HP FIRST dial one of the following phone numbers Please turn over for additional HP Support Location Phone Number U S and Canada Only Dial 1 800 333 1917withy...

Page 8: ...ase contact your local HP Response Center to see if this service is available in your country HP SupportPack Comprehensive Network Support provides complete prob lem resolution for medium to large interconnected local and wide area networks Contact your HP Authorized Reseller or the nearest HP Sales and Support Office for more information HP offers other hardware support services Please contact yo...

Page 9: ...nnectors on the front of the Remote 2C Each connector senses and selects the speed of your network and corresponds to a module installed in the back of the Remote 2C Redundant Power When the Remote 2C is connected to the HP J2962A AdvanceStack Redundant Power Supply the Remote 2C will be protected by redundant power LEDs for troubleshooting In addition to each module having LEDs the Remote 2C has ...

Page 10: ... kit 5063 8570 two mounting brackets two cable ties four M3 screws to attach brackets to Remote 2C four 5 8 inch number 12 24 screws to attach Remote 2C to rack HP AdvanceStack Product CD Australia New Zealand 8120 6810 Denmark 8120 6814 Europe 8120 6811 Japan 8120 6798 South Africa 8120 6813 Switzerland 8120 6815 United Kingdom 8120 6809 United States Canada 8120 6812 abner bk 1_instal fm5 Page 2...

Page 11: ...ounted in any EIA standard 19 inch telco equipment rack For your safety read the mounting precautions in Safety and Regulatory at the end of this guide before mounting the Remote 2C 1 Attach the mounting brackets to the Remote 2C with the included 10 mm M3 screws continued on next page Sturdy table in an isolated area abner bk 1_instal fm5 Page 3 Monday June 23 1997 2 40 PM ...

Page 12: ...l 3 Place the HP Remote 2C in the rack and lower it so the notches in the bottom of the bracket slide onto the screws Tighten these screws be careful not to overtighten 4 Install the other number 12 24 screw into the upper hole in each bracket Tighten these screws be careful not to overtighten Upperholeinthebracket Lower notch in the bracket Install additional screw abner bk 1_instal fm5 Page 4 Mo...

Page 13: ...l or wood surface that is at least 1 2 inch plywood or its equivalent Attach the Remote 2C to the wall or wood surface with 5 8 inch number 12 wood screws One Remote 2C on a wall Caution For continued safety and product cooling ensure a cover plate is installed over any open module slot Two Remote 2Cs on a wall abner bk 1_instal fm5 Page 5 Monday June 23 1997 2 40 PM ...

Page 14: ...ractor handles down Then tighten the two screws that hold it in place Be careful not to overtighten the screws Caution Replace the cover plate over the slot using the two screws that hold it in place Be careful not to overtighten the screws When using the Remote 2C without a module the cover plate must always be installed This is required not only for safety but also to ensure proper cooling 4 On ...

Page 15: ...d 10Base T or 100VG be sure to connect twisted pair cable to these connectors before powering on the Remote 2C Follow the illustrations below to connect the Remote 2C to your LAN continued on next page Slide the Module label in until each word is legible Category 3 4 or 5 unshielded twisted pair cable Example 1 Remote 2C connected to an Ethernet Switching Hub 12R LED should light if power is conne...

Page 16: ...hing Hub 12R and a 100VG Hub 14 Category 3 4 or 5 unshielded twisted LED should light if power is connected to the Remote 2C and hubs Remote 2C 100VG Hub 14 Ethernet Hub 12R pair 100 meters maximum abner bk 1_instal fm5 Page 8 Monday June 23 1997 2 40 PM ...

Page 17: ...twork to the much slower T1 or ISDN lines This will overload the WAN link with traffic In routing mode the Router will not forward multicast and broadcast packets off of the network Connecting Power using an RPS or AC Power 1 Optional This product is supported by the HP J2962A Redundant Power Supply RPS If you have this HP RPS connect the RPS to the Remote 2C now continued on next page To A 100VG ...

Page 18: ...nternet Router Module requires approximately 60 seconds If both modules are installed self test time is still approximately 60 seconds because the modules self test simultaneously During Self Test All LEDs are ON for the Remote 2C Then some of the Remote 2C s LEDs turn off while the modules are tested After Self Test LEDs For LEDs that are ON Front of Remote 2C Power RPS if connected In Use for Sl...

Page 19: ... to a 100VG network The port is not connected to any network or no slot module is present In Use green ON OFF The module is inserted in the slot correctly A module is not inserted in the slot or is inserted incorrectly Act ivity green Flickering Shows the amount of activity for the network connected to a port Link OK green On Off Flashing The LAN connected to the RJ 45 connector is providing link ...

Page 20: ... the two captured screws holding the module 3 Pull the extractor handles up 4 Pull the module out of the slot The following illustration shows the removal of the HP Internet Router Module from the Remote 2C Caution Replace the cover plate over the slot using the two screws that hold it in place Be careful not to overtighten the screws When using the Remote 2C without a module the cover plate must ...

Page 21: ... or 100VG LED for a twisted pair port is not lit when a cable is connected Verify that the cable is secure and is 4 pair Category 3 or better Try a different cable Verify that the connected device is powered on Try a different port Verify that the cable length did not exceed 100 meters Verify that the port is enabled and not disabled Verify that the module is fully inserted and the appropriate In ...

Page 22: ...ratings represent the current that could be drawn with fully loaded module slots Width 44 2 cm 17 4 in Depth 29 8 cm 11 7 in Height 6 6 cm 2 6 in Weight 4 4 kg 9 8 lb with no modules in the Remote 2C Operating Non Operating AC voltage 100 127 volts 200 240 volts Maximum current 1 3 A 0 75 A Frequency range 50 60 Hz 50 60 Hz abner bk 1_instal fm5 Page 14 Monday June 23 1997 2 40 PM ...

Page 23: ...c Noise Geraeuschemission LwA 53 dB am fiktiven Arbeitsplatz nach DIN 45635 T 19 Operating Temperature Non Operating Temperature Temperature 0 C to 55 C 32 F to 131 F 40 C to 70 C 40 F to 158 F Relative humidity non condensing 15 to 95 at 40 C 104 F 15 to 90 at 65 C 149 F Maximum altitude 4 6 km 15 000 ft 4 6 km 15 000 ft Emissions Verified to FCC part 15 Class A CISPR22 EN55022 Class A VCCI Class...

Page 24: ...16 Specifications abner bk 1_instal fm5 Page 16 Monday June 23 1997 2 40 PM ...

Page 25: ...ow at least 2 54 cm 1 inch in the front of the Remote 2C In the back of the Remote 2C allow at least 3 8 cm 1 1 2 inches of space for the power cord Ensure that the Remote 2C does not overload the power circuits wiring and over current protection To determine the possibility of overloading the supply circuits add together the amperage ratings from the name plates of all the other equipment install...

Page 26: ...nes the regulations for power cords in your country The mark is your assurance that the power cord can be used safely with the Remote 2C N o te The Remote2C does not have apowerswitch it ispowered on when the power cord is plugged in The Remote 2C s power supply automatically adjusts to any AC power source between 100 127 volts and 200 240 volts There are no voltage range settings to configure Whe...

Page 27: ...ightning or disturbances in the electrical utilities power grid Handle exposed metal components of the network with caution Servicing There are no user serviceable parts inside these products Any servicing adjustment maintenance orrepairmust be performed only by service trained personnel These products do not have a power switch they are powered on when the power cord is plugged in Documentationre...

Page 28: ...telles que la foudre ou des perturbations dans le réseau d alimentation public Manipulez les composants métalliques du réseau avec précautions Aucune pièce contenue à l intérieur de ce produit ne peut être réparée par l utilisateur Tout dépannage réglage entretien ou réparation devra être confié exclusivement à un personnel qualifié Cet appareil ne comporte pas de commutateur principal la mise sou...

Page 29: ...ni erter Metallbestandteile des Netzwerkes Vorsicht walten lassen Dieses Gerät enthält innen keine durch den Benutzer zu wartenden Teile Wartungs Anpassungs Instandhaltungs oder Reparaturarbeiten dürfen nur von geschultem Bedienungspersonal durchgeführt werden Dieses Gerät hat keinen Netzschalter es wird beim Anschließen des Netzka bels eingeschaltet Symbol für Dokumentationsverweis Wenn das Produ...

Page 30: ... andare soggetti a pericolose tensioni transitorie ad esempio provocate da lampi o disturbi nella griglia d alimentazione della società elettrica siate cauti nel toccare parti esposte in metallo della rete Nessun componente di questo prodotto può essere riparato dall utente Qual siasi lavoro di riparazione messa a punto manutenzione o assistenza va effettuato esclusivamente da personale specializz...

Page 31: ... vean sometidos de vez en cuando a voltajes momentáneos que entrañen peligro rayos o al teraciones en la red de energía eléctrica Manejar con precaución los componentes de metal de la LAN que estén al descubierto Este aparato no contiene pieza alguna susceptible de reparación por parte del usuario Todas las reparaciones ajustes o servicio de mantenimiento debe realizarlos solamente el técnico Este...

Page 32: ...24 Safety and Regulatory Statements Safety Information Japanese Safety Information Japanese abner bk 2_safety fm5 Page 24 Monday June 23 1997 2 40 PM ...

Page 33: ...alled and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area may cause harmful interference in which case the user will be required to correct the interference at his own expense VCCI Class 1 For Japan Only European Community This equipment complies with ISO IEC Guide 22 and EN55022 Class A Note Th...

Page 34: ...tion of Conformity for the HP AdvanceStack Remote 2C complies with ISO IEC Guide 22 and EN 45014 The declaration identifies the product the manufacturer s name and address and the applicable specifica tions that are recognized in the European community abner bk 2_safety fm5 Page 26 Monday June 23 1997 2 40 PM ...

Page 35: ...abner bk cvrbak fm5 Page 31 Monday June 23 1997 2 40 PM ...

Page 36: ...ion in this document is subject to change without notice Copyright 1997 Hewlett Packard Company Printed in Singapore 6 97 Manual Part Number J3257 90004 J3257 90004 abner bk cvrbak fm5 Page 32 Monday June 23 1997 2 40 PM ...