4.
If power was removed to the library, turn on the library main power switch.
5.
Close the back door of the library.
The power supply replacement procedure is complete.
Card cage expansion module power supply
Required tools
A #1 Phillips screwdriver is required for this procedure.
Replacing a card cage expansion module power supply
To remove the power supply:
1.
Identify the power supply to be replaced.
2.
Use a #1 Phillips screwdriver to loosen the captive screws in the black ejector handle at one end and
the screw at the other end.
3.
Pull the power supply out of its slot.
WARNING!
The power supply can be hot.
To install the replacement power supply:
1.
Hold the power supply with its ejector handle on the left.
2.
Slide the power supply into the card cage slot.
3.
Tighten the ejector handle screw and the mounting screw on the other end.
The power supply replacement procedure is complete.
Part number
375816-001
Location
Bottom of the card cage expansion module
Characteristics
•
Hot-swappable
•
3U x 8HP size with two LEDs
Function
Provides up to 150 W to card cage
Power supply
10471