6
•
If AC power is used, use a single-phase three-wire power receptacle with protection earth (PE) to
filter interference from the power grid.
•
Keep the switch far away from radio transmitting stations, radar stations, and high-frequency
devices.
•
Use electromagnetic shielding, for example, shielded interface cables, when necessary.
•
Route interface cables only indoors to prevent signal ports from getting damaged by overvoltage or
overcurrent caused by lightning strikes.
Laser safety
WARNING!
Do not stare into any fiber port when the switch has power. The laser light emitted from the optical fiber
might hurt your eyes.
The HP 5130 EI switches are Class 1 laser devices.
Installation tools
•
Flat-blade screwdriver
•
Phillips screwdriver
•
ESD wrist strap
All these installation tools are user supplied.
Installation accessories
Table 3
Installation accessories
Product code Description
Quantity
Applicable models
5066-0850
1 U four-hole mounting bracket kit
(including one pair of mounting
brackets and eight M4
countersunk screws)
1 kit
•
HP 5130-24G-PoE+-4SFP+
(370W) EI
•
HP 5130-24G-PoE+-4SFP+
(370W) EI TAA
•
HP 5130-48G-4SFP+ EI
•
HP 5130-48G-4SFP+ EI TAA
•
HP 5130-48G-PoE+-4SFP+
(370W) EI
•
HP 5130-48G-PoE+-4SFP+
(370W) EI TAA
•
HP 5130-24G-SFP-4SFP+ EI
•
HP 5130-24G-SFP-4SFP+ EI TAA