Make sure that the terminals, the server, and the switch can reach each other.
The host of the web user must have a route to the listening IP address of the local portal server.
Complete the configuration on the RADIUS server and make sure the authentication, authorization, and
accounting functions work normally. In this example, configure on the RADIUS server an 802.1X user (with
username userdot), a portal user (with username userpt), and a MAC authentication user (with a username and
password both being the MAC address of the printer 001588f80dd7).
1.
Configure portal authentication.
# Configure VLANs and IP addresses for the VLAN interfaces, and add ports to specific VLANs. (Details
not shown)
# Configure the local portal server to support HTTP.
<Switch> system-view
[Switch] portal local-server http
# Configure the IP address of interface loopback 12 as 4.4.4.4.
[Switch] interface loopback 12
[Switch-LoopBack12] ip address 4.4.4.4 32
[Switch-LoopBack12] quit
# Specify the listening IP address of the local portal server for Layer-2 portal authentication as 4.4.4.4.
[Switch] portal local-server ip 4.4.4.4
# Enable Layer-2 portal authentication on GigabitEthernet 1/0/1.
[Switch] interface gigabitethernet 1/0/1
[Switch–GigabitEthernet1/0/1] portal local-server enable
[Switch–GigabitEthernet1/0/1] quit
2.
Configure 802.1X authentication.
# Enable 802.1X authentication globally.
[Switch] dot1x
# Enable 802.1X authentication (MAC-based access control required) on GigabitEthernet 1/0/1.
[Switch] interface gigabitethernet 1/0/1
[Switch–GigabitEthernet1/0/1] dot1x port-method macbased
[Switch–GigabitEthernet1/0/1] dot1x
[Switch–GigabitEthernet1/0/1] quit
3.
Configure MAC authentication.
# Enable MAC authentication globally.
[Switch] mac-authentication
# Enable MAC authentication on GigabitEthernet 1/0/1.
[Switch] interface gigabitethernet 1/0/1
[Switch–GigabitEthernet1/0/1] mac-authentication
[Switch–GigabitEthernet1/0/1] quit
4.
Configure a RADIUS scheme.
# Create a RADIUS scheme named
rs1
.
[Switch] radius scheme rs1
# Specify the server type for the RADIUS scheme, which must be
extended
when the iMC server is used.