4.4.5 Fitting the neutralisation box and
the condensate delivery pump
1.
Fit condensate delivery pump. (14, Fig. 18).
14
Fig. 18
2. Remove the neutralisation box from its packaging.
Vorderen und hinteren Remove the front and rear
cover of the neutralisation box.
3.
Empty the neutralisation granulate (Neutroxide) into
the neutralisation box and distribute evenly.
Neutralisation gran-
ules (Neutroxide)
front
6
Fig. 19
4.
Remove front cover (1a, Fig. 20). Release lateral
locking bolt (1, Fig. 20) (approx. ¼ turn to the left). Lift
the front cover straight upwards and remove towards
the front.
5. Remove base plate (2, Fig. 20). Lift base plate straight
upwards and remove.
1
1a
2
Fig. 20
6. Fit rear cover (9, Fig. 21) of the neutralisation box.
7. Fit jubilee clip (10, Fig. 21) approx. 20mm from the
upper end of the hose and tighten slightly. The hose
(10a, Fig. 21) of the connection eccentric (10b, Fig.
21) must be aligned towards the left.
10
9
10a
10b
Fig. 21