3.7 Heat output
Fresh air temperature
– 5 °C
– 15 °C
Unit type
Fan speed
Q
t
S
H
max
Q
t
S
H
max
kW
°C
m
kW
°C
m
MG-6/30
1
29.2
45.5
6.3
29.2
44.5
6.3
2
29.2
38.2
9.3
29.2
37.2
9.5
MG-6/60
1
60.5
60.0
6.7
60.5
59.3
6.8
2
60.5
48.0
10.6
60.5
47.0
10.7
MG-9/60
1
60.5
51.4
6.8
60.5
50.4
6.9
2
60.5
43.2
9.8
60.5
42.2
10.0
Legend:
Q
= Nominal heat output
t
S
= Maximum supply air temperature
H
max
= Maximum mounting height
Reference:
Room air 18 ° / Extract air 20 °C / 10 % Fresh air ratio
Table E8: TopVent
®
MG heat output, supply air temperatures and mounting height
3.8 Minimum and maximum distances
X/2
X
Z
H
Unit type
MG-6/30
MG-6/60
MG-9/60
Fan speed
1
2
1
2
1
2
Unit clearance X
min.
m
9
10
10
11
11
12
max.
m
16
19
19
23
21
26
Mounting height H
min.
m
4.0
4.0
4.0
4.0
5.0
5.0
Distance from ceiling Z
min.
m
0.3
0.3
0.3
0.3
0.4
0.4
Table E9: TopVent
®
MG minimum and maximum distances
■
1
Allow a free space of 1.5 m for service
and maintenance.
E
53
TopVent
®
MG
Technical data
Technical data