INSTALLING HOUGEN CUTTER IN ARBOR
1. Disconnect from power source.
2. Lay drill on its side with feed handles up or be sure Arbor clears table
if unit is in normal operating position.
3. Turn Feed Handles until cutter mounting set screws are exposed
and completely remove the set screw.
4. Insert proper pilot in shank end of Hougen Cutter.
5. Insert Hougen Cutter until fl at on cutter shank is aligned with set
screw holes and is exactly perpendicular to axis of set screw holes.
6. Insert set screws and tighten.
8
The Coolant Bottle is Attached as follows:
Instructions for Use:
�
Screw Coolant Bottle Assy
to bracket behind motor.
�
Attach hose to Coolant Inducer
located on the Arbor
On/Off Valve
Coolant Fill
1. Fill Coolant Bottle with properly mixed RotaMagic™ Cutting Fluid.
2. Turn On/Off Valve to "On" position.
3. Press pilot gently down on work surface. (Coolant should slowly
release from bottom of cutter.)
4. Continue with drilling operation.
INSTALLATION OF COOLANT BOTTLE
Summary of Contents for 925102
Page 11: ...11 NOTES...