8
installation
&
operation
manual
|
dlv
heating
system
2.5 MOUNTING
CAUTION
!
Lifting hazard:
Proper rigging and safety equipment must be used to move this equipment. Do not lift
the heating system by any cords, electrical conduit or cabling. Create a plan before attempting to move.
Proper lifting locations are identified on each system; use these locations when lifting and mounting
the system.
Overheating hazard:
When mounting the heating tank, position the tanks so that they are completely full
of fluid while in operation.
NOTICE
Heating system damage:
Engine vibration will damage the heating system; isolate the heating system
from vibration. Never mount the heating system or components directly to the engine. If the heating
system is installed using rigid pipe, use a section of flexible hose to the supply and return ports to isolate
the heating system from engine vibration.
Improper mounting hazard:
Reference heating system component drawings before mounting the system.
Unless mounted properly, the heating system will be unstable.
2.5.1 TANK AND PUMP
Mount the heater in a vertical orientation with pumps directly below the control box
.
Reference drawings
for mounting position. When installing the heating system, note that the tanks requires a minimum of 30
inches (63.5 cm) of clearance to remove each element for maintenance.
See
SECOIO 5.1.13
.