If the one-shot safety stat operates to open circuit, the machine will be 'dead' and the display
will be blank. No fault code will display.
F14
Upper element failure
• Check security of module connector J4;
• Test between pins 4 and 5 on J4 (approximately 48 ohms);
• If open circuit, test upper element and the wiring between J4
and the heater.
F15
Upper element is on when it
should be off.
• Check security of module connector J4;
• Check connector for signs of shorting due to moisture;
• Check heater elements and wiring;
• Replace module (F15 would normally be caused by a faulty
module).
F16
Not used.
F17
Master Relay contacts
welded closed.
• Replace module.